combination fuse 中文意思是什麼

combination fuse 解釋
復合式引信
  • combination : n 1 結合,合併,混合,聯合,配合,組合。2 合作;共謀,同謀;同黨。3 〈pl 〉〈英國〉連褲襯衣。4 【...
  • fuse : vt vi 1 熔化。2 熔合。3 (政黨等)聯合,合併,融合。4 由於保險絲燒斷而電路不通。n 【電學】保險絲...
  1. The way of taking one nth out of capacitor ' s the first harmonic capacitive reactance as its nth harmonic impedance is verified whit the data from tang7c. according to the approximately estimating method, the first harmonic impedance of 220kv system is calculated. on the basis of the models, this paper gives the harmonic equivalent circuit of substation and gives the b ( n ) function of the harmonic time n. when the capacitors has different combination, b ( n ) ' s value will also change, with the inputting local measurement data, the paper studies the series and parallel resonance at the substation, and deduces that the reason the capacitor ' s fuse of tang6c is frequently interrupted is that its capacitor current contains a large number of 5th harmonics, and that the reason the discharging pt of tang7c capacitor being exploded is also that the 7th and 9th harmonic currents are amplified

    據此,對該站進行了串聯諧振分析和並聯諧振分析,並結合測試數據和有關變電站的運行記錄,指出了導致該站電容器湯6c頻繁燒保險的主要原因是5次諧波電流含量偏高,引起湯7c放電pt爆炸也是因為7次和9次諧波電流被放大。針對這些導致湯陰變電站補償電容器故障的原因,提出了相應的諧波治理措施,包括針對湯6c電容器5次諧波電流含量偏高的原因,提出了停運湯6c電容器或者通過把湯sc電容器的部分容量併入湯6c電容器(湯sc其餘部分停運)以增加湯6c諧波承受能力的措施;針對# 2變低壓側7次和9次諧波電流被放大的現象,提出了在湯7c電容器上加裝一定百分比的串聯電抗器的措施。
  2. Combination fuse - switch ( cfs ) unit compartments shall be designed and type - tested for arcing fault containment where the energy level available to the input terminals of the compartment exceeds 1, 000, 000 a2 seconds

    試譯:間隔式組合熔絲開關櫃( cfs )的隔室設計應滿足,在隔室的輸入端子的有效能級超過100萬安培秒之處,能進行閃故障包容以及閃故障包容的型式試驗。
  3. Low - voltage switchgear and controlgear - part 3 : switches, disconnectors, switch - disconnectors and fuse - combination units

    低壓轉換開關裝置和控制裝置.第3部分:轉換開關斷路器開關斷路器和保險絲組合裝置
  4. Abstract : through the analysis of the coordination characteristics between the switch and the fuses in combination, it is shown that the transfer current of combination can be decreased by reducing the prearcing time of fuses in the range of transfer current or by increasing the fuse - initiated opening time ( t0 ) of the switch. the ways to decrease the transfer current for present combinations are put forward

    文摘:本文通過對組合電器中負荷開關與熔斷器之間的配合特性分析,認為減小熔斷器在轉移電流區域內的弧前時間或適當增加熔斷器觸發的負荷開關分閘時間t0 ,均可降低組合電器所需開斷的轉移電流值,並針對現有組合電器提出了減小轉移電流的具體方案。
  5. Plant explosion - proof low - voltage switch isolating switch and fuse combination electrical apparatus

    廠用防爆低壓開關隔離器隔離開關及熔斷器組合電器
  6. Low - voltage switchgear and controlgear - part 3 : switches, disconnectors, switch - disconnectors and fuse - combination units appareillage basse tension - partie 3 : interrupteurs, sectionneurs, interrupteurs - sectionneurs et combin s - fusibles. preview :

    低壓開關設備和控制設備.第3部分:開關隔離開關開關-隔離開關和保險絲組合部件
  7. Switches, disconnectors, switch - disconnectors and fuse - combination units

    開關掣、切斷器、開關切斷器及熔斷組合器;
  8. Switches, disconnectors, switch - disconnectors and fuse - combination units ; low voltage switchgear and controlgear assemblies

    開關掣、切斷器、開關切斷器及熔斷組合器;
  9. Low - voltage switchgear and controlgear part 3 : switches, disconnectors, switch - disconnectors and fuse - combination units

    低壓開關設備和控制設備第3部分:開關隔離器隔離開關及熔斷器組合電器
  10. Specification for low - voltage switchgear and controlgear - switches, disconnectors, switch - disconnectors and fuse - combination units

    低壓開關和控制裝置規范.開關,斷路器,開關斷路器和熔燃單元
  11. Low - voltage switchgear and controlgear. part 3 : switches, disconnectors, switch - disconnectors and fuse - combination units

    低壓開關設備和控制裝置.第3部分:開關斷路器開關-斷路器和熔斷器組合元件
分享友人