drawing load 中文意思是什麼

drawing load 解釋
拉拔力
  • drawing : n 1 延引,牽引;引誘。2 抽簽;拈鬮。3 【機械工程】拔絲;沖壓成形。4 描畫,制圖;圖,圖形;素描;...
  • load : n 1 裝載,擔子;負擔;工作(負荷)量。2 (車船等的)裝載量;一馱,一車,一飛機。3 【電、機】(機...
  1. The drawing of ac load line in amplificatory circuit

    放大電路交流負載線的作法
  2. Sheet metal formability and test methods - drawing and drawing load test

    拉深與拉深載荷試驗
  3. Theoretical prediction and orthogonal experiments analysis on the drawing load of cup - drawing

    杯形件拉深力的理論預測與正交試驗分析
  4. The relative mechanisms of eliminating the structural elongation has been demonstrated after wire rope is drawn, and it, s influential factors with different drawing load has been explored

    通過實驗論證了鋼絲繩經過張拉后消除其結構性伸長的有關機理,以及在不同的張拉負荷的作用下對結構性伸長的影響。
  5. It is also pointed out that the shear stress along the flow - in direction existing near the junction of straight and curve edges is one of the major components of drawing pressure, and it is very important in the calculation of drawing load of non rotational symetrical drawing

    並且指出,法蘭直、曲邊交界附近存在的流入方向剪切力是拉深力的主要成分之一,在非回轉對稱拉深載荷的計算中非常重要。
  6. With fast development of our country " s gas industry and air ' s increasingly serious contamination in city, using gas instead of coal and supplying energy in high efficiency and cleanliness has become necessary way in city. there are different problems in the current heating ( air conditioning ) systems. in the cogeneration system, heat and power affect each other, heating - pump heating ( aie conditioning ) system can not satisfy the peak load very well, the cost of gas fuel in boilor heating sestem is so high. the high generating efficiency of the diesel - engine two - sourse heating ( air conditioning ) systems is limited in range of 100kw - 1000kw, the heating scope is so limited. combined cycle of two sourse heating ( air conditioning ) system is most suitable selection to buesness community with big scope my paper aim at this syetem ' s primary question when it is applied in our country - - - - bringing project into execution and technology economy feasibility and off - design performence, combined with a certain demonstrating project in beijing buesness community, going along with calculating and analyzing, drawing out some efficient datas and conclusions, based on this, bringing out primary alements affecting combined cycle of two sourse heating ( air conditioning ) system " economics

    熱電聯產系統熱電相互牽連,熱泵供暖(空調)系統不容易很好地滿足尖峰負荷,鍋爐供暖系統供熱中天然氣燃料構成的成本過高,內燃機雙源供暖(空調)系統的高發電效率僅限於100kw - 1000kw負荷范圍,供熱面積有限。對于大面積的商業園區、居民小區,燃燒天然氣的燃氣-蒸汽聯合循環雙源供暖(空調)系統是最佳選擇之一。本論文針對該系統在我國應用時的主要問題- - -方案的技術實施與技術經濟可行性,結合北京某一商業園區示範工程,進行了系統的計算與分析,得到了有效的數據與結論,在此基礎上,提出影響聯合循環雙源供暖(空調)系統經濟性的主要因素,並進行敏感性分析,得出有益的結論;最後通過各種供暖方案的比較分析回答了某些人對該系統的疑慮和不解,並指出系統的優化方向。
  7. One - way exhaust. load fuse box has high - speed drawing equipment to save the time and shortage

    件下端裝有熔斷件高速拉出裝置,以減少燃弧時間
  8. By effectively managing and controlling of electric load, we can improve load curve and advance using rate of power supply equipment, which can prevent from drawing strobe and limiting electricity and avoid affecting social produce and life

    對用電負荷進行有效的管理和控制可改善負荷曲線,提高發供電設備的利用率,可防止拉閘限電,避免影響社會生產和生活。
  9. Abstract : optimum design of individual foundation considering the effect of strength and deformation is discussed in this paper. the optimal mathematical model of determining the bottom surface demention of individual foundation under eccentric load is derived. the optimal solution is decided by method of optimization and the method we select is penalty fonction and complex method. the program of optimum algorithm is comiled and design and drawing of individual foundation is completed. the final results of engineering samples suggest that the cost of material and engineering amount can reduce approximatly 5 % - 6 %. a fair - sized economic efficiency can be received by using optimum method to design foundation

    文摘:筆者討論了獨立基礎在考慮強度和變形條件下的優化設計.導出了確定獨立基礎底面尺寸的優化數學模型,導出了偏心荷載作用下基礎的高度和底面配筋的計算公式,求解優化解採用最優化方法的復合形法和罰函數法.通過基礎實例和工程實例的計算表明優化設計可以節省材料和工程量5 16 .所以將本文優化方法用於基礎設計,會產生較大的經濟效益
  10. Using this analytic solution, a numeric integral can be obtained. a series of conclusions can be abstracted from the result of numeric integral : 1. the direction of response is not always downwards, sometimes maybe upwards, so the pavement may get flex drawing stress and flex pressing stress to the moving load ; 2

    利用此解析解進行數值化計算,分析數值結果可知:彎沉並非總是向下,也可能出現向上的位移,這表明道面板在移動荷載作用下受到了彎拉和彎壓的交變應力作用。
  11. Trough comparing the analysis results of two kinds of calculation model, drawing the following conclusion : ( 1 ) this structure - design satisfies the standard ; ( 2 ) in analyzing the complicated high - rise building with transfer - floor, it is very necessary to adopt at least two three - dimension - space analysis procedures with different mechanic model and use the response - spectrum analysis and time - history analysis to analyze the structure earthquake response ; ( 3 ) the calculation model with elastic slab is better than the other with being infinitely rigid in the internal slab and zero in the external slab, which reflects the real load - function situation of the structure

    通過比較兩種分析軟體的計算結果,得出以下結論: ( 1 )本結構設計滿足規范要求。 ( 2 )比較satwe和sap2000分析結果可知,對于復雜的帶轉換層的超高層建築結構應採用至少兩個不同力學模型的三維空間分析軟體進行整體計算以及採用振型分解反應譜法和時程分析法進行地震反應分析是必要的。 ( 3 )在sap2000分析中,將樓板模擬成彈性板,與satwe分析中的樓板平面內無限剛平面外剛度為零的模擬方式相比,這種模擬方式能更真實的反應結構的實際受力情況。
  12. Thirdly, with rwmsw characteristics, considering the seismic ductility character, easy work and reasonable load - bearing capacity, we set forth the structural detail drawing and some codes so that design faculty and worker use it correctly

    結合保溫模塊的特點,考慮結構延性的要求,施工方便,受力合理,提出一些節點構造和一些條文規定以供設計、施工參考,解決了保溫模塊構造問題。
分享友人