negative sequence component 中文意思是什麼

negative sequence component 解釋
負序分量
  • negative : adj 1 否定的 否認的;拒絕的 (opp affirmative); 反對的 反面的;消極的。2 (opp positive) 【電...
  • sequence : n 1 繼續;接續;連續。2 順序;程序;次第;關系;關聯。3 後果;結果;接著發生的事;後事;後文。4 ...
  • component : adj 構成的,組成的,合成的,成分的。 component motion 【物理學】分運動。 component part 組成部分...
  1. Based on the adaptive interference canceling theory and the concept of space vector, an adaptive fundamental positive / negative sequence component and harmonic component detecting method is developed. due to the close loop structure, this method has quite good robustness, and can meet the requirement of the asymmetrical control of hvdc - vsc well

    運用自適應干擾對消原理和空間矢量的概念,提出了一種基波正序分量、基波負序分量及諧波分量的自適應檢測方法,並進行了詳細的理論分析,為研究hvdc - vsc的不對稱運行控制奠定了基礎。
  2. The protector makes the over - current value, zero - phase - sequence component, negative - phase - sequence and so on as protection criterions, in protection theory ; it makes atmel 8 - bit microprocessor at89c55wd as the core, with which the lattice lcd is linked, in hardware

    該保護裝置在保護理論上,以檢測過電流幅值、零序電流為判據;在硬體實現上,以atmel單片機at89c55為核心,外接圖形點陣式液晶顯示器、觸摸式按鍵等外設。
  3. It satisfies the requirements of china standard ( gb / t 14549 - 93 ), the harmonic and negative sequence component leaded by the input of electrified railways traction load are measured in si yan qiao substation. this thesis mainly analyzes the effects on the electric elements, feeding system losses, protection system and automatic device, and proposes corresponding schemes according to the problems occurring in si yan qiao substation

    本文實測了瀘州石燕橋變電站電氣化鐵路牽引負荷注入電網的諧波和負序分量,著重分析了電力系統中電氣設備、供電網線損、繼電保護和自動裝置受電氣化鐵路諧波和負序的影響,並針對石燕橋變電站出現的問題提出了對策。
  4. A simple and easy operating criterion is put forward in accordance with the relation between positive - sequence component and negative - sequence component of stator current when the motor is in unbalance and single phase broken. based on analyzing the traditional inverse time - lag overloading protection of motors, an inverse time - lag operating equation with accumulating stator current is achieved, according to the differential equation of the heating and cooling while the current flows into the conductor

    在分析電動機傳統的反時限過負荷保護的基礎上,根據導體中流過電流時的發熱、散熱微分方程得到了累加定子電流的反時限過負荷保護動作方程,經簡化后得到累加定子電流的實用的反時限特性遞推公式。
  5. Aiming at the unsymmetrical three phase voltages from inverter after a failure, the dissertation get the relationship among the positive sequence ( ps ), negative sequence ( ns ) and the instantaneous symmetrical component of the ps, this build the foundation to detect the fault and to get the fault feature

    針對逆變器故障后的電壓輸出的不對稱性,利用對稱分量法對逆變器輸出信號進行分析,獲得了逆變器輸出信號的數字信號模型,為變頻調速系統的故障檢測與故障特徵提取奠定了基礎。 3
分享友人