  1. Through analysising the characteristics of the power system with floating neutral point deeply, the paper puts forward a new plan of single - phase to ground fault line selection on the base of s ' s signal injecton method and gives the hardware and software design. in this design, the high speed sampling and data processing is carried out through using dsp processor ; the large electrice current is drived through the application of a high - performance audio power amplifier and transformer ; the communication between host computer and detectors is realized through rs485 bus technology ; the difference multilevel frequency - selected amplifier is designed and the feeble signal of space is sampled on the base of the theory of magnetic induction ; the interface between dsp and exterior chip and rs485 interface logical is designed through using fpga ; the using of lcd module and keyboard interfacing chip makes the interface between human and machine ; the programme of host computer and detectors is designed through using blocking design method

    在本設計中,採用高速的dsp處理器,實現了對故障特徵信息的高速採集與處理;採用大功率的功放晶元與變壓器配合的方法,實現了大電流信號的驅動輸出;採用485總線技術,組建了裝置主機與多探測器之間的主從式通訊網路,實現了多干擾條件下裝置主機與多探測器的可靠通訊;設計了差分式多級選頻放大電路,採用磁感應的方法實現了對空間微弱信號的接收;利用fpga技術,實現了控制器與多外設的介面及數字信號的串並轉換;採用了先進的lcd液晶顯示模塊及鍵盤介面晶元,設計了人機信息交互的介面;採用了模塊化的軟體設計方法,開發了裝置主機及探測器的軟體程序。
  2. If only one phase - to - ground relay operates, the operated phase is tripped in a single - pole tripping scheme ; otherwise, the tree phase of the protected line is tripped

    提出了繼電器按單相設置保護方案, ?相繼電器動作跳單相,超過兩相繼電器動作認為是相間故障則三相跳閘。
  3. An automatic fault location method is proposed based on ftu after the circuit analysis of single line - to - ground fault in distribution networks

    通過對配電網發生單相接地故障后饋線的電壓、電流變化規律的分析,論文提出了基於饋線現場監控終端ftu的故障點智能定位方法。
  4. Based on the main fault - character analysis of single line - to - ground fault in non - grounded distribution networks, the location algorithms by injecting current are proposed for diagnosing and locating faults

    基於對配電網發生單相接地故障后的故障主要特徵的分析,論文應用加信診斷方法,提出了相應的接地故障定位演算法。
  5. This paper is focused on the operation of single - phase earthprotection for little earth current system. based on the analyses for several kinds of ground protections, one ground protection with the functions of line selection and ground positioning is proposed for the complex automatic and mordern management for the electric substation. by this means, the economic, reliability, safty and stable operation for the grid can be achieved

    針對小接地電流系統單相接地保護的運行進行了論述,並分析比較了幾種目前採用的小接地電流系統單相接地保護的功能及優缺點,建議採用一種既能選線又能定位的小接地電流系統單相接地保護裝置,以適應綜合自動化和現代化管理的需要,確保系統經濟、可靠、安全、穩定運行。
  6. This can fully consider the effect of the structure of transmission line and the selection of lighting parameter etc. by calculating and analyzing various of factor that affect the lightning tripping probability of 500kv double circuit transmission line, we can draw the conclusions : the result by intersecting method is more accord with the practicality circumstance than by existing standard methods, using unbalance high insulation and reverse sequence of wire can reduce the contemporary outage rate of double circuit line, reducing the footing resistance is one of the most efficiency method to reduce the back stroking rate of double circuit transmission line, the double back stroking rate and the single back stroking rate will fall by three ground wire, when the footing resistance is 10 ohm, the back stroking rate by three ground wire is 83 percent of by two ground wire

    在分析輸電線路繞擊耐雷性能時,對線路的雷電屏蔽問題進行了分析,提出對擊距法進行改進,充分考慮了風速的影響因素,編寫了具有工程實用價值的計算線路繞擊耐雷水平的程序,此方法可以充分考慮線路結構和雷電參數等對繞擊率的影響。通過對影響500kv同桿雙回線路雷擊跳閘率的各種因素進行了計算和分析,得到以下結論:採用相交法的計算結果比定義法更符合實際運行情況。採用不平衡高絕緣方式和導線逆相序排列可以大大降低雙回同時跳閘率。
  7. Firstly, a relevant algorithm is presented for locating single - line - to - ground ( slg ) fault in distribution networks, fault functions are reasoned out and analyzed for single - phase and three - phase distribution lines, and criterion measure, which are based on the frequency, phase and shape characteristics of the fault function spectrums, are also presented for locating slg faults

    首先論文對三相均勻換位線路的故障定位進行了公式推導和數值計算分析,並在頻域內對故障函數的頻譜曲線幅值、相角和頻率特性進行了分析,提出了相應的故障定位判據。
  8. At present, the devices for single - phase to ground fault line selection all have deficiencice and can ’ t be suit of the appeal of the present - day power system ’ development. it will be very significative of inventing of a new reliable and intelligent device

    國內外現有的故障選線裝置還存在一定缺陷,不能適應現代電力系統的發展要求,研製出一種高可靠性、智能化的接地故障選線裝置,對于提高小電流接地系統單相接地故障選線準確性和可靠性具有重要意義。