substation 中文意思是什麼

substation 解釋
n. 名詞 分站;變壓所;支局,分局,派出所。
a power substation 變電所。

  1. Achievable unmanned power transformer substation

    無人值班變電所的實現
  2. Lightning arresters for 6. 6 kv cubicle type unit substation

    6 . 6kv室內單元變電所用避雷器
  3. High - voltage low - voltage prefabricated cubical substation

    高壓低壓預裝箱式變電站選用導則
  4. Cubical substation series - power transformer jiangsu bright group cubical substation series

    箱式變電站系列歐式箱變
  5. Probe of substation ' s anti - flashover work

    關于變電站防污閃工作的探討
  6. The grounding grid is vital to the safety of the substation

    接地網對保證變電站安全運行至關重要。
  7. After this method is putted into practice, the number that total diagnosis nodes is thirty percent of the total grounding grid nodes. 110kv dianfa, 220 kv youting and 220 kv renhe substation grounding grid erosion optimized diagnosis experiments are done in practice

    採用優化的初步測量方法后,整個診斷所需的測量節點對數約為30 % .進行了典發110kv 、郵亭220kv 、人和220kv變電站現場實測。
  8. According to the topology of the substation and resistance measurements of down - leaders, the erosion diagnosis equation is built and the resistance variations of grounding grid branches are solved, and the erosion of grounding grid could be found through the fuzzy diagnosis regulation

    利用接地網拓撲結構圖及接地網引下線間的電阻測量值,建立腐蝕診斷方程,通過求解診斷方程,計算出接地網支路電阻值變化量,採用模糊診斷方法判斷出接地網導體腐蝕的情況。
  9. In order to obtain the most economic benefits, the paper utilized the theory of " homalographic characteristic " and " share alike compensation current characteristic " to build up the best compensation relation for " hour - current " curve applied to transformer substation and for " length - current " curve applied to distribution line

    以獲得最大經濟效益為目標,利用「等面積特性」和「補償電流等分特性」理論。推導了應用於變電站的「時間?電流」曲線關系中存在的最佳補償關系,以及應用於配電線路的「長度?電流」曲線關系中存在的最佳補償關系,及補償后的經濟效益計算模型。
  10. Abb will replace an existing outdoor 275 kilovolt ( kv ) substation now nearing the end of its service - life with an indoor substation based on compact, state - of - the - art, gas insulated switchgear ( gis )

    Abb將用基於體積較小的頂級的氣體絕緣接電開關裝置( gis )的室內變電站替換現有的服務年限將到的室外275千伏特的變電站。
  11. From the last century ninetieth, microprocessor relay protection technology has been rapidly developed and widely used in our country. it has become an inevitably flow and trend in the development of relay protection technology. but there are scarce experimental devices of microprocessor relay protection at present in our country and the devices which are being used have the defect of function single, inconvenient, and high cost etc. based on this condition, an experimental and training system for the multifunctional microprocessor relay protection and substation integrated automation is explored and developed in this paper

    從上個世紀九十年代起微機繼電保護技術在我國得到了快速的發展和廣泛的應用並已成為繼電保護技術發展不可逆轉的潮流和趨勢,但是微機保護實驗設備的開發在我國幾乎是一片空白,僅有的微機保護實驗設備也存在著功能單一、體積大、成本高等諸多缺點,基於這一現狀,本文著力研究和開發一種多功能微機保護與變電站綜合自動化實驗培訓系統。
  12. An assembly of metal-clad switchgear and a step-up outdoor substation are shown at the generating station.

    在發電站處表示出了一組帶有金屬外殼的開關裝置和一個戶外升壓變電站。
  13. The way of taking one nth out of capacitor ' s the first harmonic capacitive reactance as its nth harmonic impedance is verified whit the data from tang7c. according to the approximately estimating method, the first harmonic impedance of 220kv system is calculated. on the basis of the models, this paper gives the harmonic equivalent circuit of substation and gives the b ( n ) function of the harmonic time n. when the capacitors has different combination, b ( n ) ' s value will also change, with the inputting local measurement data, the paper studies the series and parallel resonance at the substation, and deduces that the reason the capacitor ' s fuse of tang6c is frequently interrupted is that its capacitor current contains a large number of 5th harmonics, and that the reason the discharging pt of tang7c capacitor being exploded is also that the 7th and 9th harmonic currents are amplified

    據此,對該站進行了串聯諧振分析和並聯諧振分析,並結合測試數據和有關變電站的運行記錄,指出了導致該站電容器湯6c頻繁燒保險的主要原因是5次諧波電流含量偏高,引起湯7c放電pt爆炸也是因為7次和9次諧波電流被放大。針對這些導致湯陰變電站補償電容器故障的原因,提出了相應的諧波治理措施,包括針對湯6c電容器5次諧波電流含量偏高的原因,提出了停運湯6c電容器或者通過把湯sc電容器的部分容量併入湯6c電容器(湯sc其餘部分停運)以增加湯6c諧波承受能力的措施;針對# 2變低壓側7次和9次諧波電流被放大的現象,提出了在湯7c電容器上加裝一定百分比的串聯電抗器的措施。
  14. Application of picture monitoring system in substation

    圖像監控系統在變電站內的應用
  15. The installation of fire prober in substation and distribution

    變配電室火災探測器的設置
  16. Retrofit of substation grounding network in shanghai area

    上海地區變電站接地網改造
  17. The transformer substation survived the blast with relatively minor damage to the essential components.

    經爆震波襲擊后未被毀壞的變電站的重要組件受到較小的損壞。
  18. Design code of water supply and drainage for substation

    變電所給水排水設計規程
  19. Technical code of general plan design for substation

    變電所總布置設計技術規程
  20. Dep - 4000 integrated substation automation system

    Dep 4000變電站綜合自動化系統