受影響的樓層 的英文怎麼說
中文拼音 [shòuyǐngxiǎngdelóucéng]
受影響的樓層
英文
affected floor-
The noise constantly is not affecting our normal life, for example ; just repaired the family, to the quiet at dead of night building about the water pipe noise, has caused you to be unable normally to rest, the senior citizen, the neurasthenia, the heart was not specially good and so on the community, was is unable to rest, the saint porch company produced " the down - flow pipe sound insulation wrap " the product, fundamentally has solved this problem, this product has used the advanced sound insulation, the sound absorption, the material, passed through the specialized technical many years research development, and experimented after the beijing ten plots different levels owner, the sound - insulated effect achieved above 90 %, satisfaction rate reached above 99 %, did not have an example suit, received the owners universal welcome
噪音無時無刻不在影響著我們正常的生活,例如;一個剛剛裝修完的家庭,到了夜深人靜樓上下水管的噪聲,使你無法正常休息,特別是老年人,神經衰弱,心臟不好等群體,更是無法休息,聖軒公司生產的「下水管隔聲套」產品,從根本上解決了這個問題,此產品採用了先進的隔音,吸音,材料,經過專業技術多年的研究開發,並經過北京十個小區不同層次業主試驗,隔音效果達到90 %以上,滿意率達99 %以上,無一例投訴,受到業主們普遍歡迎。Ft. of residential land. those villages that were affected included lee uk, chow uk, man uk, sha tsui, lan lai wan, ko tong, ha yeung, uk tau village, pak tam chung and pak tam au. roughly speaking, there were about 50 families living in these villages. about 300 to 400 people were resettled in sai kung town, where blocks of 5 - storey houses were built for this purpose. approximately 20 to 30 families of boat people affected, however, were resettled on land
1萬平方尺建築地,直接受影響的村落分別有李屋、周屋、萬屋、沙咀、爛泥灣等,估計居民約有50餘戶,人口至少有400 ,其中的300至400名居民被遷往西貢墟新建五層樓宇,被遷移上岸的水上人家約有20至30戶,其他受波及的村落包括高塘、下洋、屋頭村、北潭涌、北潭坳等地。Based on the analysis of bearing characteristic of the staggered truss system, a simplified calculation model of staggered truss structure under vertical loads or lateral loads is presented. after that, according to the simplified calculation model, iterate method for calculating internal forces of vierendeel staggered truss structure under vertical loads and a method for calculating member forces and lateral deflection of structure is provided. at last, a method for calculating effective - length factor of column is provided by analyzing the effect of restraint of column ends, other columns in same story and neighboring story on effective - length of columns
通過對交錯桁架結構體系受力特點的分析,確定了在豎向荷載和水平荷載作用下交錯桁架結構體系的簡化計算模型;然後,根據計算模型,提出了豎向荷載作用下空腹交錯桁架結構的內力迭代計算方法以及水平荷載作用下交錯桁架結構的內力和側移計算方法;最後,通過分析柱端約束、同一樓層其它柱子以及相鄰樓層柱子的影響,給出了柱子計算長度系數的計算方法。
分享友人