接地泄漏 的英文怎麼說
中文拼音 [jiēdexièlóu]
接地泄漏
英文
earth leakage- 接 : Ⅰ動詞1 (靠近;接觸) come into contact with; come close to 2 (連接; 使連接) connect; join; put ...
- 泄 : Ⅰ動詞1 (液體、氣體排出) let out; discharge; release 2 (泄露) let out (a secret); leak (new...
- 漏 : Ⅰ動詞1 (從孔或縫中滴下、透出或掉出) leak; drip 2 (泄漏) divulge; disclose; leak 3 (遺漏) le...
- 接地 : [電學] landing; body; ground connection; electrical grounding; grounding; earthing; earth; ground...
-
Energy consume, electric strength, insulation resistance, ground conductivity, leakage current, microwave leakage, power input, normal temperature, humidity treatment, glow wire, horizontal flame, vertical flame, tracking, ball pressure, rainproof, water splash, dustproof, salt fog, endurance, motor load test, cord flexing, cord pulling, pull & torque test, lamp replacement, construction check etc
能耗、電氣強度、絕緣電阻、接地連續性、泄漏電流、微波泄漏、功率、溫升、濕熱試驗、灼熱絲、水平燃燒、垂直燃燒、漏電起痕、球壓試驗、防雨淋、防濺水、粉塵、鹽霧、耐久性(壽命)試驗、電機負載試驗、電源線彎折、電源線提拉、拉扭力測試、燈頭互換性、安全結構檢查等。The carrier wave is modulated directly by the baseband signal at several frequency point in l band and s band. firstly, this paper clarifies the theory of i / q modulation, elaborates evm and acpl, and analyzes the effect of amplitude and phase unbalance and dc offset on evm. secondly we review the basic principle of phase locked loop and it ’ s composing parts, including the basic conception and design method of pll frequency synthesizer, especially introduce the charge pump pll frequency synthesizer in detail
首先,在闡述i / q正交調制基本原理的基礎上,通過對誤差矢量和鄰近通道功率泄漏的詳細分析,定性、定量地討論了各種非理想電路因素(如相位不平衡、幅度不平衡、直流偏差等)對調制器性能的影響;其次,介紹了鎖相環的工作原理和基本組成部分,包括鎖相環的設計和環路濾波器的設計,特別詳述了電荷泵鎖相頻率源;第三,介紹了採用直接調制技術模擬衛星信號的射頻前端的設計;最後,對整個直接射頻調制系統進行測試,結果基本上達到了課題要求。Never pipe the discharge line directly into a drainage ditch, sewer or sump
不要把排泄管直接插入排泄地漏、污水管或污水坑裡。Electronic co., ltd., a private hi - tech company, professionally makes and markets electronic instruments and gauges, such as digital torque tester, bottle cap torque tester, voltage resistance tester, grounding resistance tester, leakage current tester, insulation resistance tester and etc. lankers quality instruments and gauges are characterized by well - designed structure, high reliability and stability and outstanding performance and are well sold to users in the industries of home appliances, motorcycle, automobile, motor and pharmaceutical
市藍光電子有限公司是一家集科研生產銷售於一體的高科技民營企業,公司擁有雄厚的技術實力,以卓越的設計能力,完備的工藝控制和完善可靠的檢測手段,向用戶提供高性價比的電子測量儀器。主要產品有:數字扭力測試儀系列瓶蓋扭力測試儀系列耐電壓測試儀,接地電阻測試儀,泄漏電流測試儀,絕緣電阻測試儀等安規測試儀系列。The second chapter simply introduces the development of alternate asynchronous inverter technology and retrospects some types of energy - saving systems for hydraulic elevators. then the working principles of the project are discussed and analyzed at four different working status, i. e. light load upwards, heavy load upwards, light load downwards and heavy load downwards. and the chapter focus on the introduction of structure design of pump station, calculation and type selection of pump / motor reversible units, research on oil leakage principles of accumulator circuit, design of accumulator - pump / motor pressure - energy transformer and integrated valve blocks, etc. the last but not the least, the electrical wiring of vector inverter control cabin and design of computer control and data acquisition system are introduced
論文第二章首先簡單介紹了交流異步電動機變頻調速技術的發展概況,在回顧電梯液壓控制系統節能技術的基礎上,介紹了本課題研製的「採用蓄能器的液壓電梯變頻節能控制系統研究」的基本原理,分析了動力系統在電梯轎廂輕載上下行、重載上下行等四種典型工況下的基本工作狀態和工作方式;詳細地介紹了本課題節能系統液壓動力泵站的結構設計和參數設計,重點研究了液壓動力泵站的結構設計、液壓泵馬達可逆性問題及其選型設計計算、蓄能器迴路泄漏油損失機理的研究及其補償裝置的設計、蓄能器-泵馬達壓力能量轉換裝置的設計、多功能集成控制閥組的設計等內容;最後簡單介紹了本課題矢量控制變頻控制櫃的外部附件電氣接線、計算機控制及數據採集系統的硬體設計等內容。If there are practical difficulties for installation of the off - gas destructor, the ozone generator and the contact tank should be installed in a well ventilated area fitted with ozone leakage detector with automatic alarm and equipment shutdown device
假如實際情況難以安裝清除漏出臭氧的裝置,便應把臭氧產生器和臭氧接觸缸安裝在空氣流通的地方,並且裝上了附有自動警報器和關閉設備的臭氧泄漏探測器。The paper establishes a risk management model for natural gas stations based on risk theory and risk assessment model, takes into account the real working conditions and technical specifications of natural gas stations in our country, carries on the assessment from nine aspects, and presents the risk standard, the acceptable criterion, and the suggestive measures to control these risks
摘要以風險管理技術和風險評價模型為基礎,結合我國天然氣輸氣站場設計、施工、運行時的工況,遵循我國輸氣站場技術標準和安全規范,建立輸氣站場的風險管理模型,包括輸氣站場位置及環境、站內埋地管道、地面壓力設備、運轉設備、站內閥門、儀器儀表、工藝流程、站內甲烷泄漏、站場安全系統等9個部分,提出了輸氣站場風險標準及可接受性準則,給出了風險控制的措施。Current sensors play a very important part in the on - line insulation monitoring of electric power transmission. generally they are used to measure leakage current of ground wire. at present, use current transformer as insulation monitoring current sensor mostly
電流傳感器在電氣設備絕緣在線監測系統中佔有重要的位置,它一般通過檢測設備接地線電流來監測泄漏電流,目前多採用電流互感器作為絕緣監測用電流傳感器。Electrical accessories for domestic and similar purposes. current - operated earth - leakage circuit - breakers with auxiliary source
家用和和類似用途的電器附件.帶輔助電源的電流驅動接地泄漏斷路器This thesis is founded on the investigation of the ion migration of 500kv dc ceramic support insulators for the production of the 500kv dc ceramic support insulators. in the test system, we added the grounding switch for each circuit and the mutual switch, prescribed the four status of the current measuring program, making the measurement system more stabile
在對離子遷移試驗研究的過程中,對原有離子遷移試驗測量系統進行了改進,通過為每路泄漏電流迴路設置接地開關及公共測量開關,並在軟體上為測量迴路設定4種狀態,提高了測量系統的穩定性。The installation of a watts air gap with the drain line terminating above a floor drain will handle any normal discharge or nuisance spitting through the relief valve
連接通向地漏的排泄管的美國瓦茨氣隙的安裝將有助於處理通過安全閥排出的任何正常排放或有害的泄漏。Insulators leakage current has a close relationship with insulators contamination and humidity state, so it can provide an integrated reflection of the course of contamination flashover. the contamination flashover on - line monitoring device introduced in this paper predominates the insulators insulation degree by measuring leakage current, environment temperature and humidity. with the help of the device, an active partial aperiodic cleaning method will substitute the former passive general fixed cleaning method in order to prevent the contamination flashover to a larger extent
本文所描述的防污閃在線監測系統通過直接測量絕緣子表面的泄漏電流及環境的溫度和濕度,經過數據處理、分析、判斷,達到對絕緣子絕緣狀況實時監測的目的,以此為依據變定期的、全面的、被動的清洗為不定期的、局部的、主動的清洗,最大程度地防止污閃事故的發生。Article 20 any unit that, as a result of an accident or any other exigency, discharges or leaks toxic or harmful gases or radioactive substances, thereby causing or threatening to cause an accident of atmospheric pollution and jeopardize human health, must promptly take emergency measures to prevent and control the atmospheric pollution hazards, make the situation known to such units and inhabitants as are likely to be endangered by the atmospheric pollution hazards, report the situation to the local administrative department of environmental protection and accept its investigation and settlement
第二十條單位因發生事故或者其他突然性事件,排放和泄漏有毒有害氣體和放射性物質,造成或者可能造成大氣污染事故、危害人體健康的,必須立即採取防治大氣污染危害的應急措施,通報可能受到大氣污染危害的單位和居民,並報告當地環境保護行政主管部門,接受調查處理。Additional spills were detected when high ground water levels pushed a previously undetected spill up and into contact with the tt5000 sensor cable
另外,以前沒被檢測到的泄漏現在由於地下水位升高而接觸到tt5000感應線,並被檢測出來。Since atmospheric type vacuum breakers are subject to normal maintenance and replacement, they should be located where emergency water spillage will create no problem and where they can be accessible for inspection or servicing
由於大氣型真空斷路閥需要正常的維護和更換,因此這類裝置應該安裝在緊急水泄漏或溢出不會產生問題的地方,還要容易接近進行檢查或維修。分享友人