換氣負荷 的英文怎麼說

中文拼音 [huàn]
換氣負荷 英文
ventilation load
  • : 動詞1. (給人東西同時從他那裡取得別的東西) exchange; barter; trade 2. (變換; 更換) change 3. (兌換) exchange; cash
  • : Ⅰ名詞1 (氣體) gas 2 (空氣) air 3 (氣息) breath 4 (自然界冷熱陰晴等現象) weather 5 (氣味...
  • : Ⅰ名詞1 (負擔) burden; load 2 (虧損) loss 3 (失敗) defeat Ⅱ動詞1 [書面語] (背) carry on th...
  • : 荷名詞(蓮) lotus
  • 換氣 : 1 (屏氣后再次呼吸) take a breath (in swimming); aeration2 (通風) change of air換氣風扇 scav...
  • 負荷 : [電學] load; charge; weight
  1. Based on the analysis of pool water evaporation heat transfer and the sensible heat transfer between indoor air and pool water, deduces the calculation formula of latent load by pool water evaporation

    摘要通過對游泳館內池水蒸發熱及池水與室內空之間的顯熱熱分析,推導出池水蒸發潛熱計算公式。
  2. There are many kinds of methods dealing with fresh air supplying, such as free fresh air supplying, fresh air sucking, independent fresh air supplying, heat recovery ventilating ( hrv ), etc. it was proved that ac equipment capability and iaq has a relationship with fresh air states in fan - coiling and fresh air system

    除了無組織的新風供應方式,住宅空調系統新風供應還有新風吸入方式、獨立新風供應、新風機方式。風機盤管加新風系統中,新風處理到不同的狀態點,對空調設備擔的及室內空狀態都有影響,本文對各種新風處理狀態進行了分析。
  3. Criteria for change of compress oils used in light duty rotary oil - flooded air compressor

    噴油回轉式空壓縮機油油指標
  4. Abstract : the in servie tubular heaters built early in refineries and chemical plans have low thermal load and low heat efficiency, therefore measures for technical reform are offered, including ( 1 ) enlarging the surface area of convection tubes to increase the thermal load of rhe convection section ; ( 2 ) increasign the heat interchanging area of radiant tubes ; ( 3 ) changing the height of the chimney ; ( 4 ) using new burner with forced air supply to increase calorific capacityu ; ( 5 ) adding air preheater between the convection section and chimney to enhence the temperature of the air entering the furnace ; ( 6 ) adopting high temperature radiant coating to improve the effect of radiant heat interchanging

    文摘:針對早期建造的煉油廠和化工廠在役管式加熱爐熱和熱效率低的狀況,提出了若干技術改造措施包括,增大對流管表面積以增大對流段的熱;增加輻射管的熱面積;修正煙囪高度;用新型燃燒器,變自然通風為強制供風,以增大燃燒器的發熱量,減小過剩空系數,節省燃料2 % 3 % ;在對流段和煙囪之間增設空預熱器以提高空入爐溫度;採用高溫輻射塗料增強輻射熱效果,從而增加熱源對爐壁的輻射傳熱量和爐管的傳熱量等。
  5. The in servie tubular heaters built early in refineries and chemical plans have low thermal load and low heat efficiency, therefore measures for technical reform are offered, including ( 1 ) enlarging the surface area of convection tubes to increase the thermal load of rhe convection section ; ( 2 ) increasign the heat interchanging area of radiant tubes ; ( 3 ) changing the height of the chimney ; ( 4 ) using new burner with forced air supply to increase calorific capacityu ; ( 5 ) adding air preheater between the convection section and chimney to enhence the temperature of the air entering the furnace ; ( 6 ) adopting high temperature radiant coating to improve the effect of radiant heat interchanging

    針對早期建造的煉油廠和化工廠在役管式加熱爐熱和熱效率低的狀況,提出了若干技術改造措施包括,增大對流管表面積以增大對流段的熱;增加輻射管的熱面積;修正煙囪高度;用新型燃燒器,變自然通風為強制供風,以增大燃燒器的發熱量,減小過剩空系數,節省燃料2 % 3 % ;在對流段和煙囪之間增設空預熱器以提高空入爐溫度;採用高溫輻射塗料增強輻射熱效果,從而增加熱源對爐壁的輻射傳熱量和爐管的傳熱量等。
  6. Based on the previous research, theoretically analyses the influence of combinations of air changes and cooling load in an isolation ward and the adjacent buffer room on isolation effects when the temperature difference is considered

    摘要從理論上分析了考慮溫差影響下,隔離病房和緩沖室的次數與房間冷的匹配情況對兩室一緩工況下隔離效果的影響。
  7. According to a quantitative analysis, concludes that the matching relationship between air changes and cooling load is a major factor in determining the actual temperature difference and isolation coefficient, and that the parameters in isolation ward would play a dominant role

    通過定量分析計算,指出隔離病房和緩沖室間的溫差和隔離系數主要由兩室的次數與房間冷的匹配情況確定,而病房匹配情況的影響要比緩沖室大得多。
  8. It is indicated that hrv has many advantages certified by theoretic analyze and engineering practices, such as fully ventilating, abundant fresh air supplying, energy saving, etc. comparing with independent fresh air supplying, hrv is supposed to cause potential problems, - in summer load of fan - coil units will be increased, and the wet operating mode will be aggravated, the indoor relative humidity will be increased

    新風機供應新風是住宅空調系統較為理想的新風供應方式,本文通過理論計算及工程實踐表明採用,新風機具有充分、新風量保證、節能等優點。但與新風機組獨立供應新風相比,新風機供應空調系統新風時,會造成夏季風機盤管增加,濕工況加重,室內相對濕度有增加趨勢。
  9. According to the conclusions above, we can say that we should state a correct scale that the loads of both takes on when we design displacement ventilation and cooled ceiling system. this will ensure the air quality of the work zone ; increase cooling capacity ; reduce power lose of the ventilation system

    因此,在進行置通風與冷卻頂板混合系統設計時,需要確定一個兩者承擔的合適比例值,以在保證工作區空品質的前提下,盡量提高工作區舒適性指標。
分享友人