故障電極電流 的英文怎麼說
中文拼音 [gùzhàngdiànjídiànliú]
故障電極電流
英文
fault electrode current- 故 : Ⅰ名詞1 (事故) event; incident; happening; accident 2 (原因) cause; reason 3 (朋友; 友情) fr...
- 障 : Ⅰ動詞(阻隔; 遮擋) block; hinder; obstruct Ⅱ名詞(遮擋物) barrier; block; obstacle
- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 極 : i 名詞1 (頂點; 盡頭) the utmost point; extreme 2 (地球的南北兩端; 磁體的兩端; 電源或電器上電流...
- 流 : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
- 故障 : hitch; breakdown; stoppage; fault; faulting; accident; blunder; bug; conk; failure; impairment; i...
- 電極 : electrode; pole
- 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
-
This paper presents a method that chopping wave is done by switch devices which consist of three - level resistance regulating module and intelligence power module ipm, and which realizes constant - current discharge of storage battery. to achieve the intelligence control of the drive protection and the discharge process of ipm, the paper designs circuit formed by igbt threshold drive pulse pwm signals. ipm fault - blocking protection circuit and microcomputer 80c196. the devices can accurately control the 0 ~ 150a discharge current and the discharge time of the storage battery and calculate the releasing power
實現蓄電池恆流放電過程智能控制是蓄電池放電裝置發展的必然趨,本文提出了一種通過三極電阻調節模塊和由智能功率模塊ipm為開關器件進行斬波從而實現蓄電池恆流放電的方法。為達到對ipm的驅動保護和放電過程的智能控制,文中設計了igbt門極驅動脈沖pwm信號形成電路和ipm故障封鎖保護電路及由單片機80c196為核心的微機控制器。本裝置能夠對蓄電池進行0 150a放電電流及放電時間的精確控制及釋放容量的計算。Analysis on the magnetic pole fault of the feilaixia bulb type turbine generator
飛來峽貫流式水輪發電機磁極故障的分析Even if the fault spread from external fault zone to internal fault zone, the differential protection can avoid misoperation. main criterion of protection is composite - percentage current differential algorithm according to every sampled value, which can accelerate the protection ' s trip, reduce large amounts of calculation and have strong stability to ta saturation
本文採用基於采樣值的比率制動式電流差動保護演算法作為保護的主判據,可以明顯提高保護動作速度和減少計算量;具有較強的抗ta飽和能力,在區內故障時無制動,區外故障時有極強的制動特性。In the 3 ~ 35kv power supply system of our country, the large part is the not solidly earthed neutral system. when the single - phase earthed phenomena happens in this system, this electric power network can run with failure. and in this way the operated cost can reduce greadty. and at the same time the power supply systemic dependability can be improved. but when the single - phase earthed current is large, this electric power system can engender easily arc earthed overvoltage and interphase short circuit by this means
在我國10 35kv供電系統中,主要為中性點非直接接地系統,這種系統在發生單相接地時,電網仍可帶故障運行,這樣可以大大降低運行成本,提高供電系統的可靠性,但這種供電方式在單相接地電容電流較大時容易產生弧光接地過電壓和相間短路,給供電設備造成了極大的危害。For this reason, the general algorithm on fault calculation is researched in protection relay setting, and fast calculation on branch current is put forward for the first time in this paper. so the complete and quick fault analysis is provided for protection setting
為了滿足工程實際需求,本文作者積極探索了面向繼電保護整定計算的通用故障分析演算法,首次提出了適用於任意故障類型的支路電流的快速演算法,為保護定值的整定計算提供了完備而快速的故障分析方法。Firstly, the voltage sample signals from ac exciter stator coil were de - noised and filtered by means of decomposition of the wavelet function. secondly, the character frequency region of the rotating rectifier fault was selected clearly with wavelet package decomposition and reconstruction
先對交流勵磁機定子磁極線圈電壓采樣信號進行消噪濾波,再通過小波包分解和重構進行特徵頻率提取,建立了表徵旋轉整流器故障的特徵向量。Judging by the different magnitude and direction of the wavelet packet coefficient modular maximum, we can select the single phase - to - earth line. the method using wavelet singularity detection theory to extract the fault time is discussed. a fault distance measurement algorithm combining wavelet analysis used for separating the character from the transient fault signal with artificial neural networks used for the nonlinear approximation from the transient character to fault distance is presented
論文提出利用各個出線零序電流在頻帶上小波包系數模極大值的方向和大小的不同來實現故障選線,討論了利用小波分析的奇異性來判斷故障啟動時刻,提出將小波分析和人工神經網路結合,利用人工神經網路的非線性逼近能力,實現故障暫態量到故障距離的非線性映射,完成測距。This method uses wavelet transform to pick up the transient fault information because of its multi - resolution characteristics and time - frequency localization nature. fault line is detected based on the modulus maxima or energy comparison under some scale of wavelet transform of phase currents or component current. this method is applicable for such power system as only furnished with ct on two phases, so the shortcoming of other methods presented in recent years is overcome
即利用相應出線相電流或分量的暫態信息突變量在小波變換某一尺度下模極大值或能量比較來確定故障線路,該方法同樣適用於只裝設兩相ct的小電流接地系統,從而克服了迄今為止提出的一些選線方法在系統只裝設兩相ct時失效的問題。The results show that occurrence of the single or double pole block on the dc lines, or short - circuit faults on the dc or ac lines will not influence seriously on power system stability
模擬結果表明:當南橋、華新換流站發生直流輸電單雙極閉鎖以及交、直流側短路故障時,不會給系統帶來穩定問題。The transient analysis and simulation studies in time - domain showed that the transient capacitance current of busbar is unable to be caught due to the limitation of the given sampling frequency, therefore the transient current singularity of the fault line and the non - fault line will approximate, which prevents to identify the fault line with the criterion calculation result of transient current protection
研究結果表明,線路出口故障時暫態電流保護完全失去選擇性的根本原因是,在給定的采樣頻率的限制下,難以捕捉到過渡過程中極其短暫的母線分佈電容中的暫態電流,從而故障線路與非故障線路暫態電流波形的奇異性相近,根據故障線路和非故障線路的暫態保護判據計算結果不能正確識別故障線路。In this paper, the important point is the study about the application of wavelet analysis in single phase grounding fault location of small current grounding power systems, wavelet transform is used as a novel tool of signal analysis to obtain useful fault transient components, a new criterion of fault line selection is constructed based on the time and frequency localization character of wavelet transform
本論文主要研究了小波分析在小電流接地系統單相接地故障定位中的應用,利用小波變換這一新興的信號分析工具,提取故障時的暫態電量信息,構造出了基於小波變換模極大值奇異性檢測原理的新型選線判據。分享友人