故障電流 的英文怎麼說

中文拼音 [zhàngdiànliú]
故障電流 英文
failure current
  • : Ⅰ名詞1 (事故) event; incident; happening; accident 2 (原因) cause; reason 3 (朋友; 友情) fr...
  • : Ⅰ動詞(阻隔; 遮擋) block; hinder; obstruct Ⅱ名詞(遮擋物) barrier; block; obstacle
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : Ⅰ動1 (液體移動; 流動) flow 2 (移動不定) drift; move; wander 3 (流傳; 傳播) spread 4 (向壞...
  • 故障 : hitch; breakdown; stoppage; fault; faulting; accident; blunder; bug; conk; failure; impairment; i...
  • 電流 : current; galvanic current; electric current; electricity; current flow電流保護裝置 current protec...
  1. When circuitry malfunction happens, the current is so strong that the fuse wire melts and breaks, and the active joint is released, as a result, the fuse tube falls and the electrical circuit is shut off

    當線路發生時,故障電流使熔絲熔斷,活動關節被釋放,熔管迅速跌落,將路切斷。
  2. There is great change of negative current component when it happens the line - open fault. it is marked as the occurrence of the fault. and it can be concluded the phase characteristic of negative current in the line. in the transient course, there are plenty of harmonics in the fault line. through the transient analysis, it is drawed that the amplitude of each harmonic in fault phase is greater than other phases. harmonic current in fault line is far greater than other normal lines

    發生斷線以後,線路中會出現負序的突變,可以作為啟動判斷的標志,並且通過分析得出了時負序基波的相位特點。在暫態過程中,故障電流中含有大量豐富的諧波成分,各次諧波在期間有突變,並且衰減很快。
  3. The mutual inductor of electric current and voltage mutual inductor play an important role in relay protection. prevent from ct differential to protect and miss movement an important subject that the generatrix is protected on the saturation, put forward two electric current pass zero hour linear to spread person who become put into differential to protect in ct in recent years, avoid ct saturation district, can judge the bus bar trouble correctly

    但是在母線區外發生短路(特別是故障電流含有大量非周期分量)時, ct會出現飽和現象, ct飽和后,不能正確地傳變一次側,從而使二次發生嚴重畸變,產生很大的差,這樣就容易引起誤動作。防止ct飽和時差動保護誤動作一直是母線保護的一個重要課題,近年來提出的在ct二次過零時的線性傳變區投入差動保護,避開ct飽和區,能對母線做出正確判斷。
  4. At present, differential protection is often used as the main protection for traction transformers. however, the existing of certain factors, such as magnetizing inrush, over - excitation, ct saturation and mismatching of ct ratio, will result in that it is hard to distinguish state current and fault current, and differential protection misoperation or maloperation, then secure operation of electric railways system will be threatened

    目前,牽引變壓器通常採用差動保護作為主保護,但是在某些因數的影響下差動保護並不能準確的區分牽引變壓器內部或非內部,如故障電流與變壓器處于勵磁涌、過勵磁, ct飽和及ct變比不匹配等情況下的狀態就很難準確的區分,可能造成保護誤動或拒動,從而危及整個鐵道氣化系統的安全運行。
  5. A fault current limiter using permanent magnets has been designed and its performance simulated using a twodimensional time - stepping finite - element method incorporating a model of hysteresis for hard magnetic materials

    摘要按永久磁鐵設計製成的故障電流限制器,性能是靠含有硬磁材料的磁滯模型的2維時間分級有限元件方法獲得的。
  6. The paper analyses the principles of distinguishing internal faults current from inrush current and their defects at the present time on the basis of investigating widely the existing papers on identification of inrush current

    本文在廣泛閱讀國內外現有的關于變壓器勵磁涌識別的文獻的基礎上,分析了目前區分變壓器勵磁涌故障電流的多種原理及存在的問題。
  7. In order to meet needs of reliability and speediness of power transformer protection, and to have protection blocking reliably in the presence of magnetizing inrush current, the wavelet transform is applied to the discrimination between inrush current and fault current

    本文把小波變換應用於勵磁涌的鑒別,詳細探討了用小波變換來區分勵磁涌故障電流的具體方法,提出了兩種比較適用於工程實際的方法。
  8. Guide for the application of faulted circuit indicators for 200 a, single - phase underground residential distribution

    200a單相地下住宅分佈用故障電流指示器的應用指南
  9. Use exhausting construction to fix different problems on the same fuse box, in case the current

    採用逐級排氣式結構,在開斷大故障電流時雙向排
  10. In order to improve the behavior of transformer protection that is incomplete at present in distinguishing magnetizing inrush current from fault current, the paper puts forward a kind of new principle of transformer differential protection after analyzing the characteristic of magnetizing inrush and active power consume of transformers. this protection uses differential protection based on positive sequence active power as a criterion to discriminate internal faults from magnetizing inrush, and ratio restraint differential current protection as a signal to touch off the protection

    針對當前力系統中變壓器保護由於勵磁涌鑒別理論不完善而導致的誤動率相對較高的問題,論文在分析了變壓器勵磁涌特性和有功損耗的基礎上,提出了用變壓器正序有功功率差動作為區別勵磁涌故障電流的判據,並以成熟的比率制動差保護作為內外部判據的變壓器主保護。
  11. A dc transit system can never be fully protected because the protection cannot always distinguish between distant faults and train load currents for both of the currents have the similar magnitude and the rate of change

    在各種短路中,地鐵直側遠方短路由於其故障電流的大小和變化率都很難同正常負荷鑒別開來,所以至今難以做到百分之百的保護。
  12. This thesis chooses b spline wavelet that adapts to the analysis of power system signal, and uses the wavelet transformer to analyze the magnetizing inrush current and inner fault current. a transformer microcomputer protection was designed in this thesis, and in the base of intermission angle principle, a new criterion was established, which pierces through the traditional method with accurate measurement of intermission angle, but analyses the wave by wavelet transform. this criterion is lower in hardware, so it will be realized in the existing hardware

    本文選擇適合力系統信號分析的b樣條函數作為母小波,對勵磁涌和內部故障電流進行小波分析,並設計微機型變壓器保護基本配置,在以往間斷角原理鑒別勵磁涌的基礎上,突破傳統精確測量勵磁涌間斷角的方法,直接對信號小波變換后的波形進行分析,建立一個新的鑒別勵磁涌判據,該判據對硬體要求不高,可以在現有一般硬體平臺上實現;並編寫以b樣條函數為母小波的小波變換判據演算法程序。
  13. Guide for liquid - immersed transformer through - fault current duration

    液浸式變壓器穿越故障電流持續時間的指南
  14. Through fault current

    穿越故障電流
  15. The results indicates the new hybrid bridge type sfcl using the inductance of the superconducting state and the impendence of the normal state of the superconductor could be more efficient in fault current limiting than the traditional bridge type sfcl

    結果表明,該拓撲結構同時利用了超導體超導態的感和失超后的阻來限制故障電流,限效果好,響應和復位速度快,是對橋式限結構和混合型限原理的有意義的探索。
  16. A current limiter is designed to react to and absorb unanticipated power disturbances in the utility grid, preventing loss of power to customers or damage to utility grid equipment

    故障電流限制器能夠對公用網中意外的力干擾作出反應並消除這些干擾,防止客戶的能損失,防止損壞公用網設備。
  17. Have studied generator ground model mostly used in detail for middle and big domestic generator units. calculates and deduces fault current as grounding of single phase and third harmonic fault protection schemes. first time contributes overall knowledge about generator neutral grounding of distribution transformer with secondary resistor, in which considered inductance of the transformer to people

    針對大中型發機的兩種主要接地方式進行了分析,進行了接地故障電流、三次諧波保護的計算推導,首次在接地變高阻接地方式有關公式推導中計入接地變感抗,從而使人們對接地變高阻接地認識更為全面。
  18. Because the fault current is very small, the fault defection is difficult

    由於接地故障電流很小,因此給選線帶來了一定的困難。
  19. Because there is direct relation ship with fault currents and transient and dynamic voltages, in theory or practice, it is so complicated that the selection of generator neutral grounding model will affect or determine the generator protection scheme

    由於暫態過壓、接地故障電流等都直接與發機接地方式有關,同時還影響或決定著發機的保護形式,所以接地方式的選擇在理論和實踐上都是一個復雜的問題。
  20. Under the conditions of high safe coefficient of insulated electrical strength of the stator winding of the generator, the selection of earthing resistance value should meet the needs of matching one - point earthing protection of the stator and limiting the fault current

    在發機定子繞組絕緣氣強度有較高的安全系數的情況下,接地阻值的選取應主要服從與定子一點接地保護的配合及限制接地故障電流的需要。
分享友人