  1. Linear induction motor is an important kind of machines which have some merits such as simple structure, low cost, durability, convenience for maintenance etc. the subject of this thesis is to study a big circular ring linear induction motor, and the major works in this thesis are summarized as follows : ( 1 ) considering the effects of the finite length of primary core, one - dimension analytical solution for the air gap field is cited in this paper. based on it, the single layer winding magnetic field is studied. considering whole - pitched and short - pitched winding configuration with odd poles and half - fulled slots in both ends, the double - layer winding magnetic field is analyzed, respectively

    本文對大圓環直線感應機進行了深入細致研究,內容包括: ( 1 )本文採用限長行波面流作用於限長鐵芯上的模型,引用了氣隙磁場一維解,研究了單層繞組磁場,奇數極半填槽雙層繞組在採用整距和短距時磁場的分析、比較,簡單介紹了二維解; ( 2 )用限元軟體ansoft對大圓環直線感應機空載氣隙磁場進行了靜態分析,並分析了結果; ( 3 )用軟體進行了額下的瞬態分析,得到了轉矩,移,轉速隨時間變化曲線圖,利用單極性霍爾元件測轉速並與軟體計算結果進行了比較,採用等路法計算了堵轉時的最大磁力並做實驗進行了驗證,由實驗測得了三相流波形,並與計算結果進行了比較,對其不對稱性進行了性分析。
  2. While with the super hige voltage power network gradually built and the structure of system becoming more complex, the calculation time of optimization increases when the number of buses that need reactive power compensation is relatively large. especially, when the positions of compensation are uncertain, selecting the position of compensation can reduce time when reactive power optimizing

    而且隨著超高網的逐步形成,系統結構日趨復雜,需要安裝無功補償設備的母線比較多的時候,優化計算所需的時間將加長;尤其是在網路補償置不確的情況下,無功補償點的選擇就成為無功優化計算前節約時間的措施。
  3. Zeron has been buckling down to press related automation equipment and always provide products that achieve customer ' s cost reduction requirement from 2001, we offer : mechanical press cnc controller, digital cam, die height indicator, crank angle display, tonnage monitor, calibration load cell, and with cabinet ' s total solution for press control

    南京澤榮自動化系統限責任公司自2001年以來一直致力於力機自動控制領域產品的開發、生產和銷售以滿足客戶降低成本、提高率之需求,我們的產品包括:高速力控制系統,子凸輪,模高指示器,轉角指示器,噸監控系統,機標系統,以及帶控櫃的全套控制系統等
  4. The clamping diodes conduct only once in a switching period, and the resonant inductance current is smaller in zero state, leading to a higher efficiency and reduced duty cycle loss. the operation principle of the improved converter and the comparison with the original converter are analyzed in this paper. the effect of the blocking capacitor in series with the transformer or resonant inductance is discussed, and a best scheme is determined

    本文將諧振感和變器交換置,使變器與滯后橋臂相連,這樣箝二極體在一個開關周期中只導通一次,同時零狀態時諧振流較小,利於提高變換率和減小占空比丟失,本文分析改進后變換器的工作原理,並與改進前的變換器進行對比,討論隔直容在不同置對變換器工作的影響,確一種最佳工程方案。
  5. The value given by the command specifies more than 3 digits after the decimal point. a valid minimum warning threshold value for volts contains up to 3 digits after the decimal point

    (此命令所指的值在其小數點后超過3數。最小警告閾值在其小數點后最多保留3。 )
  6. By analyzing the refraction 、 reflection process of fault transient current traveling wave of high voltage and characteristics of refraction 、 reflection coefficient systematically, a new fault location method of single ended traveling wave is presented. it can not only identify the reflection wave for fault location efficiently, but also not be affected by the structure and length of line. fault earthed resistance 、 fault type 、 system impedance and can locate fault in adjacent areas accurately

    論文深入地分析了高線路故障暫態流行波的波折、反射過程以及折、反射系數的特點,提出了新的單端行波故障測距方法,它不僅能夠地識別出測距所用的反射波,而且幾乎不受線路結構、長短、故障接地阻、故障類型、系統阻抗的影響,在近區仍可以準確地進行測距;同時模擬阻波器的特徵,設計了低通數字濾波器,對通過了低通數字濾波器的暫態故障流行波再次進行小波分析,並利用本文提出的單端行波故障測距方法進行故障,結論是所提出的測距方法在實際應用中仍是的。
  7. For shutters, the results show : 1 ) according to the formula p =, the theoretical value of is calculated by the effective velocity of the flow, and its engineering value is calculated by the arriving velocity of the flow, the relationship between the theoretical value of and its engineering value is 2 ) the smaller value of declining angle will result in the smaller pressure loss and smaller outlet velocities. as a result, the declining angle of 30 擄 or less is recommended in some places which need small wind velocity, such as broadcasting studio and library, and the declining angle of 45 擄 or less is recommended in places which need big wind velocity, such as cinema and office ; 3 ) the larger value of ratio between the wide of the shutter b and the space between two boards h ( b / h ) will result in the larger pressure loss and smaller outlet velocities. the range of b / h from 0. 8 to 2. 0 and the optimum value 1. 2 is recommended ; 4 ) the range of b from 10 mm to 50 nun and the optimum value 40 mm is recommended ; 5 ) the proper thickness of the boards 8 of the shutters is 1. 5 mm ; 6 ) cuneiform boards should replace the rectangle inlet boards of the shutters in order to obtain better ventilation

    數值模擬採用fluent軟體,計算結果用excel進行處理,通過對大量數值工況進行數值模擬計算,結果表明:對于單側百葉風口,計算表明: 1 )對于公式p = ( ~ 2 ) 2 ,的理論計算值中義為流體流經百葉風口內部時的速度,即速度,而工程上常使用流體的來流速度來計算,計算表明,的理論計算值與工程應用值的關系為( _ (理論) ) ( _ (工程) ) = 0 . 813 ; 2 )當來流速度一時,擋板傾斜角度越小,力損失越小、出口速度越小;因此在要求進口風速比較小的場所,如播音室、圖書館等,宜採用擋板角度30的百葉風口;在要求進口風速比較大的場所,如影院、辦公室等,百葉擋板的角度應選45 ; 3 )當來流速度一時,百葉擋板的擋板寬度b與擋板間距h的比值b h越大,力損失越大,出口速度越小,計算表明,鑒于力損失、出口風速、板間形成渦流區的大小,百葉擋板的b h值取0 . 8到2 . 0之間, b h = 1 . 2為最佳值; 4 )當來流速度一時,在計算的條件下,當百葉擋板寬度b = 40mm時,百葉擋板的阻力系數最小,考慮到渦流區等的影響,建議選用10mm b 50mm的百葉擋板;西安建築科技大學碩士學論文5 )百葉擋板的厚度取為1 . sinln為好; 6 )百葉擋板的入口側可選用具傾斜度的楔形擋板來代替矩形擋板,利用其較好的導流作用,可得到更好的出流果。
  8. Prosprosing a tansformer winding model to judge whether the transformer has come into bing interturn short circuit and the degree of interturn short circuit, and providing an availability for condition monitoring of transformer that improves the accuracy of condition monitoring and fault diagnosis. 3. the accuracy and invalidity of diagnosis of fault positions and fault characters of power transformer would be improved greately if reasoning and analyzing the operation records and oringnal datums of transformer

    建立變器繞組狀態監測和故障診斷的模型,通過對繞組在線監測判斷繞組是否發生了匝簡短路、具體哪一相發生匝間短路以及匝間短路的嚴重程度,為變器狀態監測提供了的狀態監測量,實現了變器故障的局部地提高了力變器故障診斷的準確性。
  9. This thesis disusses the current states and the matter of the transformer condition monitoring and diagnosis fault. afer analying that dga can only reflect the fault type but ca n ' t confirm the fault location, part - discharging signal can realize fault location in theory but ca n ' t be carried out easily for the inconstant influence of circumstance, we present a method that conbinates the oli - gas and electric quanlities to monitor the transformer. using on - line monitoring of oli - gas conform the fault type. using on - line electric quanlities confirm the fault location. with this method, a fault diagnosis system and corresponding diangnosis flow are proprosed. the main work of this thesis consists of the following parts : 1

    本文主要研究了力變器狀態監測與故障診斷的現狀以及存在的問題,針對目前dga (油中溶解氣體色譜分析法)只能性分析變器的故障,不能進行故障,而局部放雖然能夠進行故障,但由於現場的干擾復雜多變,難以提取的局部放信號,從而提出了結合油氣量和氣量兩個方面對變器進行狀態監測。通過油氣量在線監測,判斷其故障類型和性質;通過氣量在線監測,對變器的關鍵部件? ?繞組實現故障
  10. The accurate fault location of the fault position of high voltage transmission line is principal measure for improving safety and economic performance of the power restoration of line, cut down economic loss due to the failure, which has great social and economic interests

    =高線路故障點的準確是提高網安全經濟運行的主要措施,準確的故障可以減輕巡線負擔,加快線路恢復供,減小因停而造成的經濟損失,具巨大的社會和經濟益。
  11. Consequently, it is also the most effective system location for implementing remedial measures. the significant influence of system parameters on the voltage stability are also investigated

    該母線也是採取補償措施來提高性的最置,根據圖和最小特徵值圖可以評估補償措施的果。