過載繼電器 的英文怎麼說

中文拼音 [guòzǎidiàn]
過載繼電器 英文
maximum power relay
  • : 過Ⅰ動詞[口語] (超越) go beyond the limit; undue; excessiveⅡ名詞(姓氏) a surname
  • : 載Ⅰ名詞(年) year : 一年半載 six to twelve months; six months to a year; 三年五載 three to five ...
  • : Ⅰ動詞(繼續; 接續; 接著) continue; succeed; follow Ⅱ副詞(繼而) then; afterwards
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  • 繼電器 : [電工] electric relay; relay
  1. Bimetallic thermal overload relay in ships

    船用雙金屬片式熱過載繼電器
  2. The combination seal failure / overtemp alarm relay is a specialized control for monitoring seal failure and thermal overload of one ( 1 ) submersible pump motor

    密封故障和熱故障兩用報警是一個專用控制裝置,用於監測一( 1 )臺潛水泵機的密封故障和熱
  3. Other ccc - certified, rockwell automation product lines include motor control centers, contactors and accessories, circuit breakers, smart motor controllers, electronic overload relays, pushbutton and indicators, and the control relay 700 series

    其他通ccc認證的羅克韋爾自動化產品線包括機控制中心、連接和附件、斷路、智能機控制子超、按鈕和指示,以及700系列控制
  4. The protector of electromotor have used heat relay for a long time, but heat relay not only has a dead area in the light over - loading area, but also ca n ' t protect open phase under so much circumstances

    動機保護裝置採用熱已有很長的歷史,但熱機的輕區存在著「保護死區」 ,而且對斷相保護在許多情況下起不到保護作用。
  5. Compatible with rhn bimetal overload relay and eol electronic overload relay

    有全系列配套的熱保護
  6. Thermal overload relays

    Rhn系列熱保護
  7. Study of a novel over - load relay

    新型過載繼電器的研究
  8. Time lag over - overload relay

    時限過載繼電器
  9. Thermal over - current relay

    熱力式過載繼電器
  10. When ordering overload relays, specify horsepower, voltage and full load current per motor nameplate

    訂購過載繼電器時,請註明每臺機的功率馬力、壓和滿流。
  11. Schneider electric has manufactured and installed all of the electrical equipment used to manage air conditioning systems in the olympic village, including merlin gerin circuit - breakers and low - voltage equipment and telemecanique contactors, overload relays, pushbuttons and soft starters

    施耐德氣生產並安裝了奧運村用於空調系統管理的所有氣設備,包括梅蘭日蘭斷路、低壓設備和te容接觸過載繼電器、按鈕和軟啟動
  12. Otr overload time relay

    限時
  13. Over loading protection for the solid state relay of wind valve controller

    風閥控制中固態保護
  14. The transformer that use solid state relay to realize automated regulation is explored in this issues, it change the winding turn of once side according to the voltage of second side by on - load tap - changer. thus the purpose to realize automatic steady voltage

    本課題研製的應用固態實現的有自動調壓變壓,通自動有調壓分接開關根據變壓二次側的壓自動改變變壓一次側的匝數,從而實現自動穩壓的目的。
  15. Inte are a professional manufacturer of low - voltage electrical products like circuit breaker, contacotr, relays, switches, panel meters, thermostat and other electrical components which established at 1984, every inte products is rigorously tested before being dispatched to customers, plus, we also produce all kinds of tooling molds and spare parts, as specified by our customers needs

    斷路保護,接觸,溫控本公司自1984年開始生產各種低壓氣產品,如斷路保護,接觸,溫控等,公司已通iso9002國際質量體系認證,大部分產品已通ccc , ce等國際認證,產品暢銷國際市場。
  16. The tap - changer is made with solid state relay as its working mechanism and controlled by microprocessor. this switch has totally cancelled the mechanical drive organization, by the microprocessor according to the voltage of second side microprocessor decide the working condition of solid state rely, high regulation speed, need not transition resistor, rush current is low. operating frequently ; there is no electric arc to produce, can put in the fuel tank of the voltage transformer directly ; the structure is simple, the fabrication cost is low, benefit and use widely among the voltages transformer of distribution

    其中的有調壓分接開關,它是一種完全由固態作為分接開關執行機構,由單片機控制的有自動調壓的變壓分接開關。該開關完全取消了機械傳動機構,由單片機根據變壓二次側壓的高低,決定與變壓各分接頭聯接的固態的工作狀態。調節速度快,改變分接頭時不需阻,沖擊流小,可頻繁操作;無弧產生,可以直接放在變壓油箱中;結構簡單,造價低,便於在配變壓中推廣使用。
  17. Firstly, begin with building a mathematical model of relay ' s load, or a single - phase asynchronous motor, we analyze the transient process of the spam when it starts and stops by means of qualitative and quantitative methods

    首先從的負?單相異步動機的數學模型的建立入手,分別從定性和定量兩個角度對單相異步動機的起動和停止時的瞬態程進行分析。
  18. To test the time parameter, namely, is to test the operate time, release time and bounce time when the relay ' s winding is put or removed the rated voltage. these parameters ( especially the bounce time ) are very essential to relay ' s rated load

    檢測時間參數的目的是檢查在線圈施加或切除額定壓時的動作、釋放、回跳及穩定時間,這些參數(特別是觸點回跳及穩定時間)對額定負是很重要的。
分享友人