零差式電路 的英文怎麼說
中文拼音 [língchāshìdiànlù]
零差式電路
英文
homodyne circuit- 零 : Ⅰ數詞1 (零數) zero2 (數的空位) zero sign (0); nought 3 (表示沒有數量;無) nil; nought 4 (...
- 差 : 差Ⅰ名詞1 (不相同; 不相合) difference; dissimilarity 2 (差錯) mistake 3 [數學] (差數) differ...
- 式 : 名詞1 (樣式) type; style 2 (格式) pattern; form 3 (儀式; 典禮) ceremony; ritual 4 (自然科...
- 電 : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
- 路 : 1 (道路) road; way; path 2 (路程) journey; distance 3 (途徑; 門路) way; means 4 (條理) se...
- 電路 : [訊] circuit (ckt); electric circuit; electrocircuit電路板 circuit board; 電路保持 guard of a c...
-
This article has studied the deficiency and shortcoming of various kinds of methods of the parameter measurement of transmission line at present, proposed the measurement under operation on the basis of gps, researched gps application way and error that may appear in the power system synchronal sampling, put forward the parameter computing technology based on the information of both sides of transmission line, which solved some problems that exist in the parameter measurement, especially the problem that exist in the zero - sequence parameter measurement of transmission line with mutual inductance
本文研究了目前輸電線路參數測量的各種方法,分析了其中存在的不足和缺點,提出了基於gps的輸電線路參數在線測量方法,研究分析了gps在電力系統同步采樣中的應用方式以及可能出現的誤差,在同步采樣的基礎上提出了基於雙端信息的線路參數計算方法,較好地解決了輸電線路參數測量中存在的一些問題,尤其是多回互感線路零序參數測量困難的問題。Become a kind of new electronics circuit - current - mode circuit. it is replacing the traditional design method of the voltage - mode in the high frequency high - speed signal processing realm 。 this thesis mainly discussed the modified second - generation current conveyors based on the current - mode kinds of new cuicuit components, they are stronger modified standard current - mode parts in fuctions on this foundation. mainly including the modified differential difference current conveyor ( mddccii ) 、 the fully balanced second generation current conveyor ( fbccii ) 、 ( full balances ) four - terminal floating nullor ( fbftfn ) and the current differencing buffered amplifier ( cdba ), they are all function very strong standard current - mode parts, they all can provide some circuit functions of better than general operation amplifier, because they have the voltage importation and the current importation, therefore use it since can carry out the voltage - mode signal processing circuit expediently, can also carry out the current - mode signal processing circuit expediently, and have to increase the benefit bandwidth to accumulate more widely than the voltage - mode, but have their advantages more according to the current - mode filter of the modified current conveyor, because it constitutes in brief, the filter wave function is stronger and they are better than in general use operation amplifier of many advantages, be easy to composing for example 、 high speed 、 frequency bandwidth 、 the power supply voltage requests low 、 consume small, the impedance is different from etc. advantages, otherwise they have biggish dynamic range, and flexible circuit synthesize, so they are the best active parts
從第二代電流傳輸器ccii入手,重點研究了以下幾種改進型的第二代電流傳輸器:改進的差動差分電流傳輸器mddccii 、全平衡第二代電流傳輸器fbccii 、多輸出四端浮地零器ftfn 、全平衡四端浮地零器fbftfn 、電流差分緩沖放大器cdba的電路結構及其模型。然後在此基礎上系統地研究了基於這幾種改進型的第二代電流傳輸器的濾波器的設計方法,主要方法和結果如下:利用mddccii設計了差分式連續時間電流模式低通、帶通濾波器;電流模式跳耦結構考爾低通濾波器;利用fbccii設計了帶通二階節濾波器及電流模式雙二階通用濾波器;設計了基於多輸出端ftfn的電流模式二階通用濾波器電路;通過數字化開關選擇的基於fbftfn的電流模式通用濾波器;設計了基於最少個數電流緩沖放大器(兩個cdba )的多功能通用電流模式濾波器及其在非理想因素情況下分析。設計濾波器的主要方法是採用級聯設計、運算模擬(信號流圖法)和反饋設計(跳耦法) 。And to the electric capacity type voltage mutual inductor, because it compares with electromagnetic type voltage mutual inductor, transient state its bad to respond characteristic, as circuit when making the short circuit two times trouble, the voltage two times delays dropping to zero while needing to pass certain one
而對于電容式電壓互感器,由於它與電磁式電壓互感器相比,其瞬態響應特性比較差,當線路故障而使二次短路時,二次電壓需經過一定的時延後才能下降到零。By study, we can know that when one - phase ground fault happens on the line, more far the fault location is from where relays place, more less is the difference of the two zero sequence currents, while hen one - phase ground fault happens on the other line, more far the fault location is from where relays place, more is the difference of the two zero sequence currents
研究表明,當本回線路發生單相接地短路時,在通過公式計算得出的一特定值為正時,離保護安裝處越遠,本回線路零序電流與非故障線路零序電流相位差值越小;當另一回線發生單相接地短路時,離保護安裝處越遠,本回線路零序電流與故障線路零序電流相位差值越大,該值為負時則反之。分享友人