  1. These new methods adopt the circuit information contained in the power supply line current to realize the fault diagnosis. it can increase the fault coverage, reduce testing cost and improve the quality and reliability of ics

    它通過從中提取有效的息來進行診斷,能夠提高覆蓋率,降低測試成本並提高集成路產品的質量與可靠性。
  2. Abstract : the rechargeble batteries are used for backup power internal electrically equipments and instruments. but batteries lifetime usually is shorten by overwork and then malfunctions of equipment are induced. to avoid the complexion described above, the protection circuit against overwork is designed. it is based upon the voltage comparator and regulator. it will light up a red led when the volume of the batteries discharged close upon 50 % ; it will switch off the load automatically when it discharged closing to 80 % of their energy capacity, thus overwork of batteries can be avoided and lifetime may be extended

    文摘:用蓄池做后備的系統(或設備) ,常因過放導致池提前報廢而造成設備.根據壓隨容量變化的規律,利用壓比較器和壓基準設計製作了池放保護路,當池放量接近容量的50 %時,啟動預警;當池放量達到容量的80 %時,路自動切斷負載,防止池過度放,延長池壽命,保證系統(或設備)在供恢復正常后能正常運行
  3. As to the video signal, alarm signal, control signal, are all weak electricity signal, exceedingly easily be subjected to the jam, in case the power supply system does not steady, wave propag ation is greatly, the harmonic content of power source overtops, the veins wave factors are great unduly, and even power source equipment breakdown, outputting abnormal, will be about to affect the video signal image effect, and dependability cuts downs to the security and alarming system. we adopt fast fu lye ' s mutation rule - fft alternatives, by the way of carrying fft alternatives to the local junction circuit, regulated power supply, ups ' s power source, and switch power source, thereby diagnose every degree harmonious wave content of power souse, and abnormal coefficient, compared to the normal working situation. thereby diagnose out the working condition of the regulated power supply, ups ' s power source, and switch power source

    如果有供系統不穩定、波動大,的諧波含量過高,紋波系數過大,乃至設備損壞、輸出異常等情況出現,將會嚴重影響視頻的圖像效果,大大降低防盜系統的穩定性和可靠性,我們採用快速傅利葉變換原理,即fft變換,通過對市、穩壓、 ups、開關等的進行fft變換,從而得出中各次諧波的含量及畸變系數,並將其與正常工況下的參數進行對比,從而進一步診斷出穩壓、 ups、開關等設備的運行狀況;組成監控系統的設備長期處于工作狀態,往往由於設備散熱條件不好、設備老化等原因導致設備表面溫度過高,從而影響設備的正常運行,降低設備的使用壽命。
  4. In addition, according to the safety requirements of underground electrical equipment, the fault characteristics and protection principle of asynchronous motors with single speed or double speed used in underground are simultaneously analyzed, the function parameters corresponding to the fault protection for high capacity motors are determined. at the same time, module program design method and compiled monitoring program and function subprogram are emphatically described. especially, more attention is paid to the design philosophy, operation principle, hardware block diagram and software flow chart of mcs

    根據礦井生產要求,分析了異步動機的各種特徵和保護原理,確立了每種保護的動作指標;設計了主控制板的硬體路;根據結構化程序的設計方法,設計了監控程序和各功能模塊程序;並且分析了工業生產環境存在的干擾及所產生干擾的特徵,針對不同特徵的干擾,制定了相應的硬體、軟體抗干擾措施。
  5. Alarm systems - intrusion systems - part 6 : power supplies ; german version en 50131 - 6 : 1997 corrigendum 1998

    報警設備.設備.第6部分:
  6. The principle of the fault distance measurement for small current grounding system by injecting dual frequency signal are discussed from many aspects such as the method and the characteristic of the signal, the test of the signal, the method of the line select, the algorithm of the fault distance measurement, and the method of the fault location, etc. the task adopts this kind of principle, in which the signal injection is completed by the coupling between the power source and the pt

    在詳細地說明以上三種測距演算法的基本原理后,分析各種演算法的優缺點,從注入的方法、特徵,注入的檢測,接地選線的方法,測距的演算法,及定位的方法等多個方面,論述了本課題採用的應用於小流接地系統的雙頻注入式測距原理。其中,的注入由功率通過壓互感器( pt )耦合來完成。
  7. Through research on principle and approach, this paper puts forward three new methods in power cable fault location. the first method is based on wavelet reconstruction, and the measured signal which is the difference between the faulty and sound phase current under the high voltage pulse excitation, is transformed using wavelet, and the high frequency component is reconstructed at single scale

    基於小波重構的測距方法採用脈沖作用下相與健全相的流差作為測量,利用小波變換對其作多尺度分解,然後對在高頻下進行單支重構。
  8. The rtmaad system was integrated with digital signal processing ( dsp ), global information system ( cis ), optic time domain reflective ( otdr ) meter technology, wave division multiplexing ( wdm ) technology, etc. the rtmaad system made a realization that optical cable " s abort is auto located exactly. at the same time, the rtmaad system can monitor and diagnose both the optical terminal " s fault and power " s error of the stations of the fiber optical transmission network

    Rtmaad系統綜合應用了數字處理、地理息系統、光時域反射測量和波分復用等技術,實現了光纜中斷的自動準確定位,同時將光纖系統傳輸站的光端設備和設備的監測融合到一起進行實時監測和診斷。
  9. 5. the application of the system into broken - down signal - detected project of intermediate frequency switch electrical source and getting the satisfied achievement

    將該系統應用於中頻開關檢測項目中,並取得了很好的效果。
  10. A model of an 110kv three - phase network is established by matlab / simulink spsfirstly, and the disturbance of harmonic in power system is simulated by a type - ss1electric locomotive in this model. secondly, kinds of short faults are analyzed, thestable and transient voltage waves are obtained. then, a de - noising method is presented, which is based on wavelet packettransform and has better resolution in time and frequency domain

    首先利用matlab / simulink力系統工具箱中的模塊建立了一個110kv的三相輸網路模擬模型,並以韶山1型力機車為原型,實現對網中主要諧波的模擬;然後,對該輸網路中多種短路進行了分析,並給出在穩態擾動和暫態擾動情況下的壓擾動波形。
  11. This contact is normally closed, if an error occurs short - circuit at supply voltage -, sensor or signal cable of force transducer max. output signal exceeded problems with supply voltage the output opens

    但如果有錯誤供壓短路傳感器或力傳感裝置的線超出最大輸出壓或者供發生時,觸點的輸出打開。