電阻終端 的英文怎麼說

中文拼音 [diànzhōngduān]
電阻終端 英文
resistive terminal
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
  • : Ⅰ名詞1 (最後; 末了) end; ending; finish 2 (指人死) death; end 3 (姓氏) a surname Ⅱ形容詞(...
  • : Ⅰ名詞1 (東西的頭) end; extremity 2 (事情的開頭) beginning 3 (門類; 方面) item; point 4 (原...
  • 電阻 : (物質阻礙電流通過的性質) resistance; electric resistance (電路中兩點間在一定壓力下決定電流強度...
  • 終端 : terminal; terminus; terminator; tag end; end; termination; trailing end; end point; terminating終...
  1. Normal heat shrinkable tube is universally applied in insulated protection of wire connector and terminal, soldered point, resistor and capacitor ; in anti - corrosion of metallic pod and as wire distinctive mark etc

    燃性熱縮絕緣套管廣泛應用於線連接容的絕緣保護;金屬的防腐防銹;線的標志等。
  2. The result reveals that the stress control tube comprising a composite structure of the nonlinear resistive and capacitive material shows the best performance in improving electric field distributions in cable terminations

    分析結果表明,採用由容性和非線性性材料復合絕緣結構的應力控制管時,場分佈最為均勻。
  3. The result reveals that the stress control tube comprising a composite structure of the nonlinear resistive and capacitive material shows the best performance in uniforming the electric field distributions in cable terminations under impulse voltage

    分析結果表明,在沖擊壓下採用由容性和非線性性材料復合絕緣結構的應力控制管時,場分佈最為均勻。
  4. Termination resistors should be placed only at the extreme ends of the data line, and no more than two terminations should be placed in any system that does not use repeaters

    只能安裝在數據線的最末,在沒有使用中繼器的系統中,不得使用兩個以上的
  5. For bus system installation, the focus is put on cable selection principle, installation process and antinoise measure ; for security protection equipment installation, the intrinsic safety concept, installation method equipment selection and installation under two electric power supply modes ( entity concept and fisco model ) and the bus system protection against surge voltage are illustrated ; for network component installation, the selecting, installing and integrating methods of general purpose terminators, repeaters, link equipment, bus power supply and impedance module are described

    在總線纜的安裝方面,著重討論了纜的選型原則、安裝方法和抗噪防擾措施;在安全保護設備安裝方面,介紹了總線系統中本質安全的概念、安裝方法、兩種供方式(實體概念和fisco模型)下設備的選擇與安裝以及總線系統浪涌壓的保護和設備安裝方法;在網路元件的安裝方面,主要列舉了通用器、中繼器、鏈路設備、總線源及其抗模塊等的選擇、安裝和集成方法,為總線系統的安裝提供了可以借鑒的實用經驗。
  6. The simulation results indicate, deep - trench junction termination with certain width, depth and filling with isolated dielectric can increase the avalanche breakdown voltage of devices to above 95 % of the ideal value

    結果表明:具有一定寬度、深度且填充絕緣介質的深阱結結構,止了結的橫向擴展,並能將器件的雪崩擊穿壓提高到理想值的95以上。
  7. Further more, the distribution of electric field in cable termination is analyzed as cavities reside on the interface of a capacitive and a nonlinear resistive material

    進一步分析容性和非線性性材料知其分界面處含有氣隙時的場分佈。
  8. Designers and registered electrical workers may be uncertain whether conductive parts such as metallic bathroom accessories, metallic windows or metallic door handles are extraneous conductive parts. when difficulties are encountered, you may carry out a measurement as illustrated in figures 4 and 5. in figure 4, a is an exposed conductive part with a resistance rcpc to main earthing terminal

    附圖四載列外露非帶金屬部分a及懷疑為非氣裝置金屬部分b (例如是金屬水喉管或木門的金屬手柄) , a對總接地抗為rcpc , b對地的抗為rx 。
  9. Harmonized blank detail specification for lead screw actuated non - wirewound preset potentiometers - square form, container sealed, actuating device insulated from resistive element, slipping clutch at each end of travel, rigid terminations - assessment level s

    導螺桿傳動非線繞預調位器協調空白詳細規范.正方形的容器密閉的與元件絕緣的驅動裝置每個行程止的滑動離合器剛性.評定級別s
  10. Thermocouple and thermal resistance in power station suit to measure temperature of electric generator groups and auxiliary machine correspond to 300000 and 600000 kilowatt, which can substitute one from import with many advantages as shock - proof, pressure - resistant, long in service, and convenience in maintain etc. the protective tube is processed in a special construction by deep - blind hole technology whose end not be welded to enhance the strength and prolong service life. thermocouple or thermal resistance

    本公司生產的站專用熱,適用於我國30萬60萬千瓦等發機組及輔機的測溫需要,產品安全可替代進口,具有防震耐壓使用壽命長,維修方便,保護管是採用深盲孔技術加工而成,部不用焊接,提高了保護管的強度和使用壽命,鎧裝熱偶熱採用彈簧壓著式結構,在運行中保護管與鎧裝熱偶熱測量保持著良好的接觸,抗震動,減少熱響應時間,鎧裝熱偶測量採用絕緣形式,能防止磁干憂。
  11. A good rule of thumb is if the propagation delay of the data line is much less than one bit width, termination is not needed

    一個好經驗法則是:如果數據線的傳播延遲遠小於一個位寬度時,就不必使用
  12. Telecommunications - telephone terminal equipment - resistance and impedance performance requirements

    信.設備.抗的性能要求
  13. The dominant module uses a different resistor and capacitor than a standard module

    主要模塊採用的容與標準模塊不同。
  14. The value of the bias resistors is dependent on termination and number of nodes in the system

    偏置的值取決于的大小及系統的節點數。
  15. The conventional connection circuit as the figure shows for two - wired transmitter : handhold terminal palm computer and external communication interface or mainframe communication circuit cannot directly bridges in the ends of power source. but may either meet on field ends a and b or meet on the ends of load resistance b and c. in the above - mentioned case, the circuit are supplied by power source

    對兩線制變送器來說,傳統的連接路如圖所示:手持掌上腦和外接通訊介面或主機通訊路不能直接跨接在源兩,但既可接于現場兩a , b上,也可接在負載b , c ,兩種情況下,路都要通過源來供, hart規范允許負載為2301100 。
  16. Recommendations for preferred diameters of wire terminations of capacitors and resistors

    容器和線的優選直徑的推薦標準
分享友人