高電壓實驗室 的英文怎麼說

中文拼音 [gāodiànshíyànshì]
高電壓實驗室 英文
high voltage laboratory
  • : Ⅰ形容詞1 (從下向上距離大; 離地面遠) tall; high 2 (在一般標準或平均程度之上; 等級在上的) above...
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 壓構詞成分。
  • : Ⅰ形容詞1 (內部完全填滿 沒有空隙) solid 2 (真實; 實在) true; real; honest Ⅱ名詞1 (實際; 事實...
  • : 動詞1. (察看; 查考) examine; check; test 2. (產生預期的效果) prove effective; produce the expected result
  • 電壓 : voltage; electric tension; electric voltage
  1. There are over 80 sets test apparatus in tech - innovation centre, including : anechoic chamber, vibration tester, vibration measurement analysis, impact instrument, constant temperature and humidity facilities. salt spary test case, circle insulation withstand voltage tester, insulation resistance tester, withstand voltage tester, electric lead tester, electrical leakage tester, earth resistance tester, chassis dynamometer, chassis dynamometer control system, high stability dc resistance tester, electrical capacity tester, temperature rise test system

    中心擁有各類分析測試儀器和試裝置80餘臺套,包括:消音振動臺噪聲振動測試分析系統沖擊儀恆溫恆濕儀鹽霧試箱匝間耐分析儀絕緣阻分析儀對地耐分析儀泄露流測試儀對地阻測試儀測功機測功機控制系統精度直流阻測試儀參數測試儀帶溫升測試儀復合式三坐標測量儀萬分投影儀及功測試分析系統等。
  2. Methods : hyperosmotic pressure animal model was established by administering 3 % sodium chloride as drinking water to rats or increasing osmotic pressure of the culture medium. osmoregulation positions in the brain, reciprocal projection pathways between the medullary visceral zone ( mvz ) and supraoptic nucleus ( son ) or hypothalamic paraventricular nucleus ( pvn ), oscillation of intracellular calcium in cultured neurons and astrocytes were studied by means of anti - fos, glial fibrillary acidic protein ( gfap ), tyrosine hydroxylase ( th ) or vasopressin ( vp ) multiple imrnunohistochemical staining, immuno - electronic microscope, wga - hrp retrogradely tracing and cell culture methods. results : ( 1 ) fos positive neurons within the mvz, parabrachial nuclei, locus ceruleus, pvn, son, subfomical organ increased markedly

    方法:通過給予大鼠飲用3氯化鈉或提培養基滲透濃度的方法復制滲刺激模型,主要採用抗fos 、膠質原纖維酸性蛋白( gfap )和酪氨酸羥化酶( th ) (或加素? vp )免疫組織化學多重染色、免疫鏡、 wga - hrp束路追蹤結合免疫組織化學多重染色、細胞培養等方法,系統觀察了中樞參與滲透反射的調控部位、下丘腦視上核( son )神經元? ast超微結構的變化、延髓內臟帶( mvz )和son及下丘腦旁核( pvn )之間往返投射通路和神經元的性質及其與ast的關系、培養神經元和ast內鈣波的變化。
  3. For the circuit - breakers of rated voltage 252kv up, the synthetic test methods are introduced according now condition because of the limitation of the transformer short - circuit capacity. the correlative prescribes on switching line - charging current in gb / t1984 - 200x " alternating - current high - voltage circuit - breaker " are discussed according to the test results and theoretic analysis

    由於開合空載架空線路試源側的阻抗有明確的規定,這就要求試源必須具有足夠大的短路容量,很難滿足要求,因此,一般對較等級的斷路器採用合成試方法,本文介紹了利用現有條件,對252kv以上等級的斷路器採用合成試時的試線路。
  4. High - pressure lab in high - pressure electric porcelain factory

  5. Safety requirements for electrical equipment for measurement, control and laboratory use - particular requirements for autoclaves and sterilizers using toxic gas for the treatment of medical materials, and for laboratory processes

    測量控制和氣設備安全性要求.醫用材料處理及處理用使用毒氣的消毒鍋和消毒器專門要求
  6. Safety requirements for electrical equipment for measurement, control, and laboratory use - part 3 - 042 : conformity verification report for iec 61010 - 2 - 042 : 1997 - particular requirements for autoclaves and sterilizers using toxic gas for the treatment of medical materials, and for laboratory processes

    測量控制及氣設備的安全要求.第3 - 042部分: iec 61010 - 2 - 042 : 1997合格鑒定報告.醫療材料處理和操作用毒氣滅菌器和消毒器的特殊要求
  7. Safety requirements for electrical equipment for measurement, control, and laboratory use - part 3 - 041 : conformity verification report for iec 61010 - 2 - 041 : 1995 - particular requirements for autoclaves using steam for the treatment of medical materials, and for laboratory processes

    測量控制及氣設備的安全要求.第3 - 041部分: iec 61010 - 2 - 041 : 1995合格鑒定報告.醫療材料處理和操作用蒸汽滅菌器的特殊要求
  8. An integrated on - line insulation monitoring system of high - voltage capacitive equipment is designed and developed, and has been debugged in laboratory. the impact of operation is all right

    最終設計與開發出一套完整的容型設備絕緣在線監測系統,目前已完成調試,運行效果良好。
  9. Initial recovery voltage and peak recovery voltage across the circuit - breaker have an essential affect on re - strike. for assessing performance of circuit - breaker, the higher inductance and lower inductance must be considered at the same time when testing according to theoretic analysis, the directly test circuit on switching the no - load overhead by high - voltage circuit breakers of rated voltage 252kv and below, in compliance with the correlative standard jb5871 and the test devices, and the test circuit parameters have been calculated and the many testes have been carried out

    在理論分析的基礎上,考慮現有設備的情況依據標準jb5871的規定,選用合適的試設備,對試線路的參數進行計算,在建立了252kv及以下等級斷路器開合線路充流直接試線路,利用該線路進行了數臺產品的試,分析了試結果,並根據試結果和理論基礎討論了gb t1984 - 200 《交流斷路器》 (報批稿)關于開合線路充流試的有關規定。
  10. Safety requirements for electrical equipment for measurement, control and laboratory use - particular requirements for autoclaves using steam for the treatment of medical materials, and for laboratory processes

    測量控制和氣設備安全性要求.醫用材料處理及處理用蒸汽消毒鍋專門要求
  11. Finally the high voltage thyristor vale was tested in lab. the results illuminate the good insulation structure, reliable triggering and blocking, good voltage division on each thyristor, and that the bod protecting circuit acts rapidly. in a word the high voltage thyristor vale satisfies the expected specification in the application of auto - passing over neutral section of traction power supply system

    最後論文對晶閘管閥在進行的各種試進行了分析總結,試結果表明,該晶閘管閥絕緣結構合理,觸發和關斷可靠,元件在各種工況下的均一致性良好,過保護路動作迅速,達到了在牽引供網自動過分相裝置應用中的技術要求。
  12. In the way based the scientific and tecdrical talks on i presided at and panicipated in, the graduation theis included a p1entful thets in recent years wtll be divided into three parts for depiction conxteniently and clearly, according to the content as fo1lowsf ( l ) the study of shock compression properties with the drixtiir - liquid co and n, experimentally ( 2 ) the study of the phenomenon of excess heat produced by deuteriurn atoms entering into the lattice of titaluxn experimentally ( 3 ) the calcujation for the electronic structure and energy of hydrogen atoms cluster ffi. the mainstream in the first part of the paper is to exposure some experimental tecndques in high pressure and high temperatur shock compression physics, including by using a cryo - target cooled down circulating steaxned n, to condense the well - proportioned mixed liquid sample from pure gas co and n = with equal molar voiurne

    根據近幾年所承擔和參加的科研任務,將研究成果總結寫成的論文按以下三個部分敘述: ( 1 )液體co和n _ 2混合物沖擊縮特性的研究(由國防科技重點基金項目96js75 . 2 . 1 . jw1902資助) ( 2 )重氫原子進入鈦晶格中引起過熱現象的研究(由國家自然科學基金10145002資助) ( 3 )氫原子團簇h _ 9的子結構與能量計算第一部分以沖擊波物理為主,採用自行研製的低溫循環汽冷靶冷凝制樣技術由純co和n _ 2氣體獲取等摩爾體積均勻混合的液體沖擊初態樣品。
  13. In the condition of lab, for the device of power supply that based on special ct, the experimental results showed that the circuit of power supplies can supply thepower above 400mw for the high potential circuit of ect when the current in linechangefrom6ato900a. thedeviceissomepracticality

    設計製作的小ct供裝置,條件下的結果表明,採用小ct在線供方案在線路流從6a到900a的范圍內變化時,能為路提供不少於400mw的功率,基本滿足設計的要求,具有一定的用價值。
  14. It compares and analyses the equipment test voltage emendated to standard atmosphere conditions with the equipment nominal withstanding voltage. and then it concluded that : the emendation value educed by " humidity ratio " integrated emendation method is basically equal or close to the equipment nominal withstanding voltage ; but the values by two traditional emendation methods are mostly higher. it also proves that, " humidity ratio " integrated emendation method is more perfect than any other methods, and it can reflect the influence degree of atmospheric parameters on electrical equipment outer insulation discharge voltage actually

    文中選擇「比濕」綜合校正法和兩種傳統校正法,分別對西所為羊八井、拉薩、羊湖110kv變所設備所做的人工氣候模擬試數據及雲南中試所做的zs - 110工頻放數據進行校正計算,將試的校正值與試設備的標稱耐受水平進行比較分析;認為: 「比濕」綜合校正法的校正值與設備耐受水平基本相等或接近,而兩傳統校正法的校正值大多於設備耐受水平;進一步證明, 「比濕」綜合校正法是目前諸多校正法中較為完善的,能真地反映大氣參數對氣設備外絕緣放的影響程度的校正法,在海拔力工程設計中應推廣應用。
  15. Such pulsewidth and peak power introduces extreme physical conditions such as high temporal resolving power, strong electromagnetic field and high pressure. and these introduced a comprehensive and profound revolution in fundamental and technology science

    這樣的脈寬和功率密度帶來了前所未有的時間解析度以及強場,強磁場,強和溫度的極端物理條件,引發了基礎科學和技術科學一場廣泛而深刻的變革。
  16. Ganfa has over 50 years experience of designing and manufacturing and has many items of patent techninque. the synchronous generators and permanent magnet generators which are manufactured with advanced technology and excellent machining equipement, will be able to meet the requirement of different technical condition which matched with various type turbines. ganfa has manufactured the generators of 0. 1 to 20mw in capacity which have been put into operation at present and owns the capability to manufacture the following generators : the capacity per unit up to 180mw, the stator outer diameter of generator up to 9, 000mm, the speed of vertical type generator up to 750r min, and thespeed of horizontal type generator up to 1, 500r min, both the b - grade and f - grade insulation class, the terminal voltage can up to 13. 8kv. ganfa manufactured 34, 500kw water turbine generator sets for the donghewan power station, yongchang, gansu, china which is located in 2. 868. 5m height above sea level, and has successfully solved the difficult problems such as plateau corona - shielding. ganfa is equipped with the generator test station and insulation material laboratory which are advanced test facilites and testing means to make each item electrical performance of products meet designing requirements from purchasing to delivering

    公司具有50年的設計製造經,擁有多項專利技術,生產的同步發機永磁機技術工藝先進,製造精良,能滿足與各式水輪機配套的不同技術條件要求。目前公司已製造投產的發機容量范圍為0 . 120mw ,具備生產單擊容量50mw的能力,發機機座號最大可達9000mm ,立式機最轉速750r min ,臥式機最轉速達1500r min ,絕緣等級有b級和f級,圈式線圈最達13 . 8kv ,公司製造的甘肅永昌東河水站34500kw水輪發機組,海拔為2868 . 5m ,成功解決了原防暈等難題。公司擁有機試站絕緣材料試等先進的設施和測試手段,使產品從原材料進產,到成品出產的各項器性能測試均能滿足設計要求。
  17. On the basis of the former work with piezoelectric sensors of our lab, we proposed a series of piezoelectric bulk acoustic wave sensors. these sensors rely on the sensitive response of pqc and the specific selectivity of mip

    本文在本已有的傳感前期研究工作的基礎上,基於pqc靈敏的響應性能,結合mip的特異識別性能,研製出了一系列體聲波模擬生物傳感器,極大地提了pqc的選擇性。
  18. In laboratory, this system has fulfilled the measurement of simulant large current and high voltage, with the precision better than 1 % to the fundamental wave

    中成功測量了模擬大流與,基波測量精度優於一級,對其它各次諧波的測量精度滿足國家標準要求。
  19. Experiment of preparation ultra - fine - crystalline and nanocrystalline metal was performed using self - developed electromagnetic impulse high - pressure rapid solidification method

    使用自行研製的磁脈沖快速凝固裝置,進行了制備超細晶、納米晶金屬的
  20. Electrical equipment for laboratory use - part 2 : particular requirements for autoclaves and sterilizers using toxic gas for the treatment of medical materials and for laboratory processes

    氣設備.第2部分:用有毒氣體處理醫用材料和過程用釜和滅菌器的特殊要求
分享友人