shear joint 中文意思是什麼

shear joint 解釋
剪切接頭;剪節理
  • shear : vt vi (sheared 〈古語〉 shore; shorn sheared)1 剪(羊毛等);修剪(樹木);剪(呢絨的)長毛。2 ...
  • joint : n 1 接合,榫接合處,接合點。2 【解剖學】關節。3 【植物;植物學】節。4 【電學】接頭。5 【建築】接...
  1. Based on the analysis of mechanism for joint region, the " frame - wall " and " aslope compression stub column " mechanical models and yielding patterns of core zone of the joints are set up. the shear load - carrying formulation for joint core zone is also given in terms of plastic ultimate analysis. and then, the comparisons between the formulas given in this paper and that of chinese design code ( draft ) and nonlinear fem as well are presented

    對節點核心區的抗剪,通過受力機理的分析,建立了鋼「框架剪力墻」加混凝土「斜壓短受力體系及其屈服機制,根據塑性極限分析,給出了節點核心區抗剪承載力計算的迭加公式, 《規程》公式和非線性有限元近似模擬分析結果進行了比較。
  2. Compressive shear strength of dowel joint

    套接壓剪強度
  3. Copper has been deposited on surface of the al mmcs as interlayer by magnetron sputtering, tlp bonding of al mmcs with these interlays, the joints shear strength of tlp bonding using deposited film was as much as the joint shear strength of tlp bonding using cu foil. removing the oxidation on the surface before deposition, copper was coated by magnetron sputtering as tlp bonding interlayer

    待連接表面通過磁控濺射法沉積銅膜作為中間層進行瞬間液相連接,得到的接頭強度與銅箔中間層進行瞬間液相連接得到的接頭強度相當,而使用磁控濺射法去除待連接表面氧化膜后沉積銅膜作為中間層進行瞬間液相連接的接頭強度提高7 . 6左右。
  4. Methods of test for ancillary components for masonry - determination of shear load capacity and load displacement characteristics of shear ties and slip ties couplet test for mortar joint connection

    圬工輔助砌塊的試驗方法.剪切桿和滑動桿的拉伸和壓縮負載容量和負載轉移特性的測定
  5. Methods of test for ancillary components for masonry - part 7 : determination of shear load capacity and load displacement characteristics of shear ties and slip ties couplet test for mortar joint connections

    圬工輔助成份試驗方法.第7部分:拉伸和壓縮負載容量和墻系柱和負載代替特性測定
  6. A study on the shear rheology of rock joint plane

    巖石節理面剪切流變的試驗研究
  7. A determination method of joint shear strength

    結構面抗剪強度的一種確定方法
  8. The work done in this paper is mainly as follows : ( 1 ) the wide beam should intrude to the wall at some length to make the flexural stress uniform along beam section width, thus make full use of the beam ' s bearing capacity and avoid the shear failure in the concrete joint. and it also prevents stress focus and concrete crack in the local shear wall

    關于寬梁與薄墻肢節點,可以得出以下幾點初步結論:寬梁應該深入墻肢一定的深度,以使寬梁截面的彎曲應力沿著梁截面寬度分佈均勻,充分發揮寬梁的抗彎能力,同時避免節點區混凝土的剪切失效,也避免剪力墻的局部因為受到的應力過大而拉裂。
  9. Based on the experiment results, the damage form of abnormal exterior joint are summarized, characteristics of hysteresis curve are studied, the effect of stirrup ratio and height of column section and beam section on anti - shear property of abnormal joint are discussed, working mechanism of abnormal exterior joint is researched, the conclusion that the anti - crack and bearing capacity of abnormal joint are studied by analyzing the minor core of abnormal exterior joint is proposed, the basic data is provided for the design formula of abnormal joints

    根據試驗結果,總結了異型邊節點的破壞形態,研究了節點滯回曲線的特徵,討論了節點核芯配箍率、樑柱截面高度變化對異型邊節點抗剪性能的影響,分析了異型邊節點的受力機理,提出應以「小核芯」為分析單元來研究此類節點抗裂和承載力的建議,為異型節點設計公式的建立提供了基礎數據。
  10. Methods of test for ancillary components for masonry - determination of shear load capacity of welds in prefabricated bed joint reinforcement

    圬工輔助砌塊的試驗方法.預制基地加固處接頭的剪切負載容量的測定
  11. Methods of test for ancillary components for masonry - part 3 : determination of shear load capacity of welds in prefabricated bed joint reinforcement

    圬工輔助成份試驗方法.第3部分:預制床連接處增強的焊接剪切負載能力測定
  12. ( 2 ) from the equilibrium conditions of the isolated segment from a beam - column sub - assemblage, it is clarified for the first time that the bond stress along the beam rebars passing through the joint transfers into the column end to balance shear at this column end at the same ratio as that of the compression force in the compressed concrete at beam ends

    通過對樑柱組合體柱脫離體的平衡條件,首次明確了貫穿節點梁筋粘結應力和梁端受壓混凝土的壓力以相同的比例傳入柱端以平衡柱端剪力,從而對節點區的傳力機理重慶大學博士學位論文結出了完整的和具有說服力的解釋。
  13. With the diversification of people ' s esthetic sentiment to upholstery, the staggered reinforced concrete frames are used more and more widely. specifications for staggered joint are n ' t contained in code for design of concrete structures gb50010 - 2002, so, the research on shear transfer mechanisms ; seismic behavior and shear resistance of staggered joints is urgent

    隨著人們建築室內審美情趣的日益多樣化,錯層框架結構在國內應用越來越廣泛,目前的《混凝土結構設計規范gb50010 - 2002 》中還沒有針對錯層節點的專門規定,因此,對鋼筋混凝土錯層節點的傳力機理、抗震性能和抗剪承載力的研究就顯得尤為迫切。
  14. Predictions were made on the ductility of the joint core when shear compression ratio, reinforcement contant and axial force ratio were different

    進一步利用jap程序預測了不同剪壓比,不同配筋特徵值及不同軸壓比條件下節點區的延性變化規律。
  15. Based on measurement of strains of both horizontal stirrups in the joint core and longitudinal reinforcement passing througth the joint, in different stages, transfer mechanism and factors affacting seismic behavior of the joint, were analysed. under different shear compression ration, effect of axial force ratio on seismic behawior of the joint was also evaluated, static shear and seismic shear of the joint based on capacity design were investigated. on this basis, new governing criteria and conditions of seismic behavior of the joint were put forward

    通過對節點區水平箍筋以及貫穿節點梁、柱縱筋在不同受力階段應變的精細量測,對節點的傳力機理以及影響抗震性能的因素進行了分析研究;對不同剪壓比條件下軸壓比對節點抗震性能的影響規律進行了分析研究;對不同受力階段梁筋的粘結退化規律以及節點區的剪切變形進行了分析研究;對節點的靜力抗剪與建立在能力設計思路上的抗震抗剪問題進行了深入研究,提出了建立在新思路基礎上的節點抗震性能控制準則和控制條件。
  16. Based on the pseudo - static experimental results of nine abnormal joints, the damage process of abnormal joint is divided into four stages of original crack, entire crack, ultimate state and failure, the effect of axial force ratio, stirrup ratio and height of column section on seismic behavior of abnormal joint are discussed, the conclusion that anti - shear capacity of abnormal joint are studied in entire crack state by studying the minor core of abnormal joint is made, the calculating formula for anti - shear capacity of abnormal joint is proposed with a view to asymmetry in stirrup yield

    摘要根據9個鋼筋混凝土框架異型節點試件的擬靜力試驗結果,指出異型節點受力過程分為初裂、通裂、極限和破壞4個階段;討論了軸壓比、節點核芯配箍率、柱截面高度變化對異型節點抗剪性能的影響;提出應考慮節點核芯區箍筋屈服的不均勻性並在通裂狀態下以「小核芯」為分析單元來研究此類節點抗剪承載力的建議;最終給出了異型節點抗剪承載力的計算公式。
  17. The influence of such parameters as axial load index, aspect ratio and percentages of lateral reinforcement, on seismic performance of reinforced concrete frame column in hong kong and analyses the distribution relationships of flexural deformation, shear deformation and slippage of longitudinal reinforcement in joint zone

    根據試驗結果,討論了軸壓比、配箍率、剪跨比等參數對其抗震性能的影響,分析了水平荷載作用時塑性鉸區的彎曲變形、剪切變形和縱向鋼筋粘結滑移變形所產生的位移在框架柱總水平側移中所佔的比例及其變化規律。
  18. The problem two is the stirrup in the core of beam - column joint was insufficient because of designing or construction. so the shear capacity and ductility of beam - column joint will decrease

    框架節點核芯區柱箍漏放或數量不足,引起節點抗剪承載力降低,延性不足。
  19. The following conclusions are gained : ( 1 ) the located shear band prongs the ligament near the top crack tip and the structure may occur shear - mode fracture at the angle of 155 ? to crack when load is 87. 92mpa ; the mode of fracture of the flange joint structure is not possible to be void - mode ; ( 2 ) it is proved that loading and then unloading repeatedly can not increase the possibility of invalidation of the structure when the times of loading and unloading are not too more when load is operating pressure ; the structure is safe when the vessel is operating ; ( 3 ) in the fe model of the thesis, not considering the influence of water pressure test which is in the process of fabrication of vessel in fe results in larger deviation in analysi

    得出了以下結論:在8792mpa的載荷下筒體一封頭連接結構處的集中剪切帶貫穿韌帶,可能發生沿與原裂紋線成155 「角方向剪切型斷裂;筒體一封頭連接結構不可能發生韌窩型斷裂; ( 2 )在工作壓力下進行次數不多的反復加、卸載,結構不會破壞,也不會喪失安定性:結構在工作狀態下是安全的; m在本文的彈塑性有限元模擬計算中,對于裂紋尖端進行力學分析時,不考慮壓力容器製造過程中水壓試驗的影響,將導致計算結果出現較大的偏差; ( 4 )筒體完全屈服時的載荷為92石3mpa ,封頭完全屈服時載荷為86
  20. Method of shear test for side fillet welded joint

    側面角焊縫抗剪試驗方法
分享友人