逆冷凝 的英文怎麼說

中文拼音 [lěngníng]
逆冷凝 英文
retrograde condensation
  • : Ⅰ形容詞1 (方向相反) contrary; counter 2 [數學] inverse; converse Ⅱ動詞1 (抵觸; 不順從) go aga...
  • : Ⅰ形容詞1 (溫度低; 感覺溫度低) cold:冷水 coldwater; 你冷不冷? do you feel cold?; are you feeling...
  • : 動詞1. (凝結) congeal; curdle; coagulate 2. (注意力集中) fix
  1. The air thermal cnergy water heater creates the new generation hot water cquipments. it makes use of the negative card promise successfully, drieing a hot pump with the elcctrie power. equiping through a hot pump medium of compesing parts evaporate a machine. hot pump, congealed machine and inflate valve, urge the work quality completes evaporationt absorb calories within air continuously compress compress congealed reduce expenses evaporate of the thermody name energy cirenlation proess, transfer the calories in the environment to the water thus in, transfer the in great quantities free calories in the air to the life to use a water in

    空氣節能熱水器是創新一代熱水設備,它成功地運用卡諾原理,用電能驅動熱泵,通過熱泵裝置中的構成部件-蒸發器,熱泵,器和膨脹閥,促使工質不斷完成蒸發(吸收空氣中的熱量)壓縮節流蒸發的熱力循環過程,從而環境的熱量轉移到水中,將空氣中大量免費的熱量轉移到生活中水中
  2. Material balance and energy balance equations of complex multi - effect evaporation system were expressed in matrix equation, which has the advantages of clear structure and high modularization. by holding or omitting correlation block - matrix in matrix equation, matrix equation could be used to describe the difference of forward - feed, back - feed and cross - reed multi - evaporation system with or without solid separation, extra steam being led off to preheat material liquid, condensation water flash, or solution flash. the models include design and operation

    該模型利用矩陣方程具有結構清晰和高度模塊化的特點,將復雜多效蒸發系統的物料及熱量衡算方程組以矩陣形式表達,通過保留或舍棄矩陣中特定功能模塊,模型就能代表有或無固相析出、有或無引出額外蒸汽預熱原料液、有或無水閃蒸、有或無溶液閃蒸等不同情況以及各種情況任意組合的併流、流、錯流多效蒸發過程,從而實現模型的通用性。
  3. The research results show that the counter - flow condensers have a better performance than that of other arrangements in single - circuit condensers, and that branch flow should be adopted in multi - rows condensers to decrease the pressure drop and increase the heat transfer capacity, and that the influence of gravity force can not be ignored, and that there must be an optimum refrigerant mass flow which can make the condenser perform best when the air velocity is constant while there must be an optimum air flow which can make the condenser perform best when the refrigerant mass flow is constant

    研究結果表明,單迴路器中,流布置換熱效果最好,叉流其次,順流最差;多排管器應盡可能採用分流方式,以減小壓降,增強換熱;布置器流程時,重力的影響不可忽略;當風量不變時,必然存在一最佳製劑流量使器性能達到最佳;當製劑流量保持不變時,也相應存在一個最佳風量使器性能最佳。
分享友人