進風量 的英文怎麼說

中文拼音 [jìnfēngliáng]
進風量 英文
air input
  • : 進構詞成分。
  • : Ⅰ名詞1 (空氣流動) wind 2 (風氣; 風俗) practice; atmosphere; custom 3 (景象) scene; view 4 ...
  • : 量動1. (度量) measure 2. (估量) estimate; size up
  1. The theory overall illuminates how the investment company proceeds the stock choice and turns the stock choice into the concrete number by turning six factors given weights that affect the result of the stock choice into the probability of the stock choice by the quantitative method. the important points lie in : 1 considering the external environment, the growth nature, the venture and the corporate v alue ; 2 overcoming the non - comparability of the financial ratios between the corporations of different lines

    此理論從公司的外部環境和公司的內部因素全面地闡述了投資公司如何行股票選擇,以及通過對成長性、公司所處的險、宏觀及行業、公司的價值和處于不同行業的企業間財務比率化處理,將影響股票選擇的六大因素賦以權值后轉化成股票選擇的可能程度值,從而將股票選擇用具體的數值來表示。
  2. Brings forward the basic network cell model of symmetrical blast vault and asymmetric blast vault. then studies and analyses airflow in vault of main voltage switchyard hall of xiluodu hydropower station which is far cry and large numbers of airflow conflux, brings forward concept of “ virtual embranchment ” and corresponding basic network cell model, regresses calculate expressions of flux uniformity coefficient and impedance of “ virtual embranchment ” of vault of main voltage switchyard hall of xiluodu hydropower station

    而後又採用cfd數值模擬的方法對溪洛渡水電站主變洞排拱頂這種多股氣流匯流的長距離通道內的氣流流動行了分析,提出了「虛擬分支」的概念和相應的網路基元模型,並回歸得到了溪洛渡水電站主變洞排拱頂各個排「虛擬分支」均勻系數以及阻抗的計算公式。
  3. We can use new functions to adjust the casements angle and lead wind to enter ; adjust indoor entered wind quantity and direction

    二利用新功能隨意調整窗扇開啟的角度導入室內通換氣。調節室內的進風量和方向的目的。
  4. In this paper, the author established the model of objective evaluate parameters of sound quality and develope d an objective evaluation system which could give quantitative objective evaluate parameters, such as loudness, sharpness, roughness, psychoacoustics annoyance ( pa ) etc. paper also describes an subjective evaluation investigation ir " " hich 16 subjects used pair comparison statistical evaluation methods to evaluate the noise character of room air - conditioners, the results show that there is generality good agreement between quantitative objective evaluate sound quality parameters and subjective evaluation. at the same time an example of application of the technique to improve the noise character of room air - conditioner is offered

    此外本文還介紹了一個應用聲質評價技術改kfr - 50hw / e2d空調器聲質的實例,通過對空調器室外機管系、導流罩、出網等行改,空調器的聲質得到了明顯改善:在室外提高164m ~ 3 / h情況下,聲音響度下降16 ,波動強度明顯改善,尖銳度指標也略有下降,作者同時總結了不同改措施對產品聲質影響的方式,以期為今後的聲質提供借鑒。
  5. Using the post processing tools of this cfd software, this article analyses the temperature and velocity field in the vav air - conditioned office and finally evaluates the indoor air distribution, adopting air diffusion performance index ( adpi )

    利用cfd軟體的后處理工具對不同送方式以及不同工況下的變空調室內的溫度場和速度場行了分析,最後採用空氣分佈特性指標對空調室內的氣流組織行了綜合評價。
  6. Through the research work of this article, it is shown that cfd technology can efficeintly instruct the design of indoor air distribution and evaluate indoor air quality and ventilating effect ; the distribution of heat sources have great impact on indoor air distribution ; under variable air volume condition, the indoor temperature and velocity fields are quite even and the thermo - environment is relatively good when using diffusers with coanda effect such as square diffuser and slot diffuser to supply air

    經過本文研究發現,利用cfd技術可以有效地對空調室內氣流組織設計行指導,全面對室內空氣品質和通效果行評價。熱源分佈對于空調室內的氣流組織具有極其重大的影響。在變條件下,利用具有良好貼附效應的送口如方型散流器和條縫口送,空調室內的溫度場和速度場較均勻,室內的熱環境良好。
  7. Here a number of factors must be taken into consideration, such as the environmental standard of the area where the engine room is located, the fender structure of the engine room as well as the engine type, power level and the cooling air volume, etc. the core of the overall control is the concept of " equal sound insulation ", which means to apply a closed fender structure to isolate the engine unit from outside parts so as to cut the outward sound radiation

    經過多年來與環保部門的合作,對油機房行消噪聲處理,積累了一些治理經驗,主要是必須根據具體的機房項目來確定相應的控制方案,這其中應考慮機房所在區域的環境標準,機房圍護結構形式及油機機型、功率、冷卻等因素。綜合控制的核心是等隔聲概念,即用一封閉的圍護結構將機組與外界隔離開來,減少聲源對外的聲輻射。
  8. Then the air distribution system of the above - mentioned hotel ' s multi - function - hall was simulated with fidap, and the indoor temperature and velocity under the preliminary option was calculated. under the half - load condition of small air - supply quantity and slow velocity, finds that the problem has arisen, which the cold jets fall too fast in summer and the air distributes layer upon layer in winter

    然後應用fidap對上述旅館的多功能廳空調氣流組織初步方案行了數值模擬計算,預測了該初步方案的室內溫度、速度分佈,發現在送和送速度小的半負荷工況下,會出現夏季送時冷射流過早下降,冬季送時氣流分層分佈的現象。
  9. Principle of operationthe ring hammer granular crusher makes use of impact hitting hammer rings cross mounted on the rotating rotor to crush materiel. after first crushed by impact force of hammer rings, the materiel is then pressed, sheared and ground between crushing plate and ringhammers to the required granular product which flows off the screen, and those uncrushed such s tramp iron, wood pieces, stone etc will be brought into the tramp iron trap. this crusher features little blast wind, less vibration andlong, service life of vulnerable

    工作原理環錘式破碎機利用旋轉的轉子帶動環錘對物料行沖擊破碎,被沖擊后的物料又在環錘和破碎板、篩板之間受到壓縮、剪切、碾磨作用,使物料達到所需的粒度,被破碎后的物料經篩板的柵孔落下,不能被破碎的鐵塊、木塊、石塊等經撥料板撥除鐵室.本機具有鼓小、振動值小,環錘等易損件壽命長等特點。
  10. In this paper, from the viewpoint of basic automatic control system, a cooling tower supervisory controller is designed and tested by applying it on the digital simulator to real time control the tower airflow and tower fan sequencing in central air - conditioning

    摘要從集中空調冷卻水側基本自動控制系統的局部角度出發,設計了冷卻塔扇上位機控制器,對和運行臺數行實時控制,並通過模擬試驗分析了其對系統控制穩定性和系統能耗的影響。
  11. Abstract : performance evaluation on five kinds of dust collectors installed in the 2nd phase progress project of pangang, its efficiency and the comparison of measured parameters of air quantity with design parameters were taken in paper. the results showed that the electric dust collectors, water dust scrubbers, large bag dust extractions and cyclone dust collectors performed satisfactorly, small bag dust extractions took the bad with the good, and foam dust collectors went badly

    文摘:通過對攀鋼(集團)公司二期工程上馬的5種類型除塵器性能行監測評價,重點對除塵器除塵效率和處理的實測值與設計值相比較,調查監測結果表明:電除塵器、水膜除塵器、大型布袋除塵器和旋多管除塵器性能良好;小型布袋除塵器運行情況良莠不齊,泡沫除塵器運行情況差。
  12. In this article, simulations of air distribution in the vav air - conditioned office are carried out in the cases of different air - supplying diffusers including slot diffuser, sqaure grille, bar grille and square diffuser to supply air, the standard three - dimensional k - ? two - equation turbulence model with correctional item of buoyancy effect and simple algorithm are adopted, and wall function method is used to handle boundary conditions

    本文採用經過浮升力項修正的-兩方程模型和simple演算法,應用壁面函數法處理邊界條件,對利用包括條縫口、方型百葉口、長條型百葉口和方型散流器不同型式送口送的變空調房間內的氣流組織行了模擬。
  13. And, this thesis return as to it ' s measure to measure the proceeding error margin the analysis, and was analyzed by error margin the enthalpy different laboratory matchs the gb / t 7725 - 1996 standard, can be used for measuring the making the cold and making the heat ' s ability, the consuming, the cop, the breeze deal under the steady state or not steady state of air condition of diagraph room, and it can also test the influence of the four channels change to the face valve and and the electronic expanding valve to the whole function of the air condition

    而且,本論文還對其測行誤差分析,經誤差分析該焓差室符合gb t7725 - 1996標準,可用於測房間空調穩態及非穩態製冷能力和制熱能力、工耗、 cop以及空調器室內機組的,並能測試四通換向閥、電子膨脹閥等控制元件對空調器整體性能的影響。
  14. 3. the thennal balance has been founded after the ventilation rates and the heat transfer were analyzed. 4

    對豬舍的傳熱和通行分析,建立豬舍的熱平衡,計算不同豬舍通要求。
  15. The other fan can be throttled down to minimize the amount of air brought in during cold weather operation

    冷天作業時,另一個扇的可以調低,以減少機房的
  16. Now, being the chief lawyer and president of the board of partners, he is also the consultant on legality affairs of guangzhou political consultative conference, guangzhou law society and youth law of society, arbitrator of guangzhou arbitration committee, as well as the member of its panel of experts

    擔任多家政府部門法律顧問及境外銀行和跨國公司中國法律事務的常年法律顧問,在大陸、粵、港、澳商界享有相當的知名度,自90年代初開始率先?大型房地?業務提供集團式法律服務,經年累積?廣州市引的資金, ?投資者及其他當事人提供豐富的房地?開拓、融資安排、防患險、化解糾紛及訴訟、仲裁代理服務。
  17. Whole scheme of frame design of test - bed is proposed as : the host fanner supply the firebox the once and twice air required by diesel oil ' s burning and the cooling air ; the export parameter of the test - bed is varied by the adjust of the flux of air and diesel oil. and the air flux is varied by adjusting the rev of the fanner adjusted by transducer and the corner of the fan inlet adjusted by step motor. the quantity of oil is varied by adjusting the oil valve adjusted by step motor ; the measurement of the air flux in the test - bed adopts the method of fanner dynamics performance test in the nation criterion

    確立了實驗臺結構設計方案:主機為燃燒器提供燃燒所需的一次、二次進風量及冷卻;利用變頻器調節主機轉速、用步電機調節門開度來調節,用步電機調節回油閥開度來調節供油,從而實現對模擬實驗臺出口煙氣熱流的調節;實驗臺的流採用機動力性能測試標準中測流方法等。
  18. Whole scheme of frame design of testing flat is proposed as : the host fanner supply the air required by flamer ’ s burning and cooling, the export parameter of the flat varies by different rotate speed of the fanner 、 angle of the fan inlet and the quantity of oil, the measurement of flow in the testing flat adopts the method of fanner dynamics performance test in the nation criterion

    確立了實驗臺結構設計方案:主機為燃燒器提供燃燒所需的一次、二次進風量及冷卻;模擬實驗臺出口煙氣熱流是通過調節機的轉速、門開度及燃油來改變;實驗臺的流採用機動力性能測試標準中流方法等。
  19. Gravel layer is a usual complex instable formation in drilling engineering. there are some basic features such as looseness of structure, increment, unequal sized grain. it is commonly to form discrete single - grained structure

    在三個計算式的基礎上採用visualbasic編制了潛孔錘同心跟管鉆進風量壓計算及空壓機選型程序。
  20. Different disposal style for the reburning air & burning out air ( tangential or front and rear walls ) and their disposal heights. 2. different momentums of ofa ( under the condition of constant airflow of primary area and condition of constant flux inputted simulated boiler )

    冷模試驗范圍包括: 1 、再燃和燃盡的不同布置方式(切向布置和對墻布置) 、布置高度; 2 、不同燃盡(爐內總進風量不變和燃燒器主氣流不變兩種情況) ; 3 、再燃、燃盡的不同組合與主氣流之間的混合。
分享友人