load coil 中文意思是什麼

load coil 解釋
負載線圈
  • load : n 1 裝載,擔子;負擔;工作(負荷)量。2 (車船等的)裝載量;一馱,一車,一飛機。3 【電、機】(機...
  • coil : vt vi 卷,盤繞,(把…)盤[卷]成一圈 (up)。n 1 (一)卷,(一)盤,(一)圈。2 螺旋管,蛇管。3 ...
  1. The voltage ir on core adopts semienclosed insert model. the current element adopts two - stage compensation to have wide load property. the whole plasticenclosed voltage coil. can withstand instantaneous large voltage impulse. the double jewels bearing or the magnetic - propelled bearing can ensure long lifetime. the bipolar aluminium nickel cobalt damping magnet steels have high coercivity, stable magmetic property. the electric function is in accordance with iec521 international standard

    :電壓鐵芯採用半封閉插入式,電流元件採用二級補償使表計具有寬的負載特性。全塑封的電壓線圈能稱說瞬時大電壓沖擊。雙寶石軸承或磁推動軸承確保表計長壽命。
  2. The paper analyzes the non - lineal relations of the quantity of heat exchange and water flux of coil exchanger in part - load operating condition, the shortage of deciding the water flux in bypass pipe, the disadvantage that the operating condition of pumps and chiller ca n ' t be met with the load change of the air conditioning system in different operating condition of using pressure - difference bypassing control in primary water pump system. using load control method in the change of the operating condition of primary water pump system can realize that the load change is small and reasonable in the on / off condition of pumps and m m chiller by comparing load control method in primary variable - flow water pump system with pressure - difference bypassing control method, back water temperature control method

    本論文從目前空調工程中使用的變流量水系統入手,研究了盤管換熱器在部分負荷下水流量與換熱量的非線性關系,分析了文獻中介紹的旁通管通流能力選擇的不足之處和一次泵水系統採用壓差旁通控制時,工況轉換不能滿足系統控制要求的缺陷;比較了一次泵變流量水系統中壓差旁通控製法、回水溫度控製法、負荷控製法的精確性,並得出了在一次泵水系統的工況轉換時,採用負荷控製法能使冷水機組及其相應水泵在啟停時的負荷變化范圍較小,更符合建築物的冷量需求,節能效果較好的結論。
  3. It is indicated that hrv has many advantages certified by theoretic analyze and engineering practices, such as fully ventilating, abundant fresh air supplying, energy saving, etc. comparing with independent fresh air supplying, hrv is supposed to cause potential problems, - in summer load of fan - coil units will be increased, and the wet operating mode will be aggravated, the indoor relative humidity will be increased

    新風換氣機供應新風是住宅空調系統較為理想的新風供應方式,本文通過理論計算及工程實踐表明採用,新風換氣機具有換氣充分、新風量保證、節能等優點。但與新風機組獨立供應新風相比,新風換氣機供應空調系統新風時,會造成夏季風機盤管負荷增加,濕工況加重,室內相對濕度有增加趨勢。
  4. Firstly, the experimental phase current and input power data obtained from load test are employed to estimate the parameters in ii rated condition. then, the phase current and input power data in locked rotor condition are used to track the variation of the parameters of the secondary coil with slip frequency. the classical method and the direct modification method are also used to estimate the parameters of the induction machine in comparison with this technique

    首先利用了負載試驗的定子電流和輸入功率數據來識別額定工況下的電機參數,然後又使用了堵轉時的定子電流、輸入功率數據來識別電機二次繞組參數隨轉差頻率的變化,並與傳統參數測試方法和直接修正參數法進行了比較。
  5. This paper also analyzes the errors of the algorithm with arc extinguishing coil and user load in the system, and explains its practicability and feasibility

    本文還分析了系統在帶有消弧線圈和用戶負載時此種測距方法的誤差,並說明了此種方法的實用性和可行性。
分享友人