converted variable 中文意思是什麼

converted variable 解釋
變換了的變量
  • converted : 改造的
  • variable : adj 1 易變的,變化無常的,無定的 (opp constant steady)。2 可變的,能變的;變換的。3 【數學】變...
  1. Culture of mg7 hybridoma cells and detection of antigen - binding affinity of mg7 mab by elisa 2. construction and identification of mg7 recombinant phage antibody library mrna was isolated from cultured mg7 hybridoma cells and converted into cdna ; the variable fragments of heavy and light chain were separately amplified and assembled into scfvs with a specially constructed dna linker by pcr. the scfvs dma was ligated into the phagmid vector pcantabse and the ligated sample was transfered into competent e. co / / tg1 to generate a bacterial form of mg7recombinant phage antibody library ; volume and recombinant ratio of the library were evaluated by means of bacterial colony counts and restriction analysis ( ecor i and hind iii )

    Mg _ 7重組噬菌體抗體庫的構建及鑒定從培養的mg _ 7雜交瘤細胞中提取並分離mrna ,反轉錄成cdna ;利用pcr分別擴增mg _ 7單抗的重鏈及輕鏈可變區基因,並通過? dna連接子將二者連接起來形成mg _ 7單鏈抗體基因;將mg _ 7單鏈抗體基因插入pcantab5e ;將連接產物轉化感受態tg1大腸桿菌,制備細菌形式的mg _ 7重組噬菌體抗體庫;通過菌落計數和限制性酶切分析( ecor和hind )評估mg _ 7重組噬菌體抗體庫的容量和重組率。
  2. A chirp scaling algorithm for airborne bistatic sar is proposed, which is suitable for the flight configuration that transmitter and receiver follow parallel path with equal velocity in broadside looking mode. airborne bistatic sar echoed signal model of this particular flightpaths is derived. the model is converted into the range doppler space and is mapped from double range variables to single range variable domain

    本文建立了這種特殊飛行模式下雙基地sar的回波信號模型,推導了它在距離多普勒域的表達式,解決了信號模型從雙距離變量域向單距離變量域轉化的問題,並推導了cs因子的線性近似表達式,分析了演算法中各種近似造成的誤差。
  3. Optimal periodic control with the lowest operational cost by limiting total substrate discharge mass was studied. through adding new state variable and using supplement functions, the problem with restriction conditions was converted into nonrestriction problem. in addition, the dynamic searching method of optimal step coefficient was developed to modify the conventional gradient method, consequently the calculation problem of the multivariable optimal periodic control was able to be resolved better. it was found that the operational costs of optimal control under various initial states are distinctly different. a new concept of optimal control under optimal initial state was presented. it is pointed out emphatically that to the treatment system without optimal control condition, the suboptimal control with extensive practical value can be realized according to the results of optima control

    著重研究了在限制有機物排放總量時,使其運行費用最低的最優周期控制問題.通過增加新的狀態變量和用補償函數法,將本課題的有約束條件問題化為無約束條件問題,並提出了最優步長參數的動態搜索法來修改傳統的梯度法,從而較完善地解決了多變量最優周期控制的計算問題.研究中還發現了不同初始條件下最優控制所需要的運行費用也大不相同,進而提出了最優初始狀態下最優周期控制的新概念,這對保證出水質量的同時進一步降低污水處理成本來說具有更重要的意義.本文還強調指出:對于尚不具備實現最優控制條件的處理系統,可根據最優控制的研究結果實現具有廣泛實用價值的準最優控制
  4. Changed " a variable that can be implicitly converted to

    定義中的「可隱式轉換為
  5. Finally, degree reduction of interval rational triangular b - b surfaces is discussed. the problem is also converted to degree reduction of bi - variable polynomials with upper bound. according to degenerating conditions of triangular b - b surfaces, an optimization model is constructed and optimal solutions under certain constrains are calculated

    先將該問題轉化為雙變量多項式的限制上界的降階問題,然後採用最優化方法,結合三角b - b曲面的退化條件,建立約束優化模型,求出約束意義下的最優解。
  6. The main features of the system are as follows : ( 1 ) there is no direct mechanical connection between engine and wheel, so the engine can be adjusted to work at high efficiency zone. ( 2 ) the power of the engine can be transmitted to driving axle directly by the electromagnetic force, and only part of power is converted from mechanical energy into electric energy, so the power losses in energy conversion can be reduced. ( 3 ) the system can also operate as electronic continuously variable transmission

    其特點是:發動機獨立於車輪運轉,可始終在高效區工作;發動機的動力主要通過電磁力直接傳給驅動橋,僅有少部分動力經過機械能電能機械能的轉換,降低了能量轉換過程中的損失;且該系統兼備無級變速器的功能。
  7. To solve the problems in the design and operation of constant flow chilled water system, the thesis suggested that the chilled water system could be converted from constant flow to variable flow. in this thesis, the possibility of the conversion, the characteristics of vwv system and the optimized method in the designing of chilled water system were deeply studied

    針對定水量系統設計及運行中常出現的問題,本文提出了將定水量系統改造為變水量系統的課題,研究了定水量系統改造為變水量系統的可行性,分析了變水量系統的特性,同時對空調冷水系統的優化設計方法進行了深入研究。
  8. Converted controlled variable

    變換了的受控變量
分享友人