cooling water outlet 中文意思是什麼

cooling water outlet 解釋
冷卻水出口
  • cooling : n. ,adj. 冷卻(的)。
  • water : n 1 水;雨水;露;〈常作 pl 〉 礦泉,溫泉;藥水。2 〈常 pl 〉水體;水域;水道;海;湖;河;海域;...
  • outlet : n. 1. 出口,出路;排水口;通風口。2. 【商業】銷路。3. 批發商店。4. 發泄(情感)的方法;排遣。5. 地方廣播電臺[電視臺]。
  1. When temperature changed, in order to keep the outlet temperature of the cooling water stable, we can change the areas of draught deflectors, so the speed and area of the draught is changed, which will improve the safety and economy of the running assembling sets with the assumption of economizing water in winter

    當外界溫度發生變化時,為保證出塔水溫不發生變化,可通過改變擋風板面積的方法,使進風口面積及進塔風速發生改變,進而保證出塔水溫,保證冷卻塔在冬季的正常運行。
  2. There are several important issues to that attention should be paid in the design of test bed, such as the measurement of the temperature difference between the inlet and outlet of test section and the temperature of cooling water in the inlet and outlet of condensing tubes, filled volume of the steam boiler and its level control, the determination of the natural acting head of high temperature tank and design of the cooling water flow of measuring tank

    試驗臺由高溫工質自然循環子系統、冷卻水機械循環子系統和計算機監測控制子系統構成,試驗段進出口溫差及冷凝管進出口溫度的測試、蒸汽鍋爐充注量及液位控制、高溫水箱自然作用水頭的設計、冷卻水流量計量水箱的設計等是試驗臺設計中值得重視的問題。
  3. After the optimizing system is put into operation, online calculating results and operation effect is analyzed, pointing out that the base for the whole boiler soot blow optimization is the minimum loss of soot accumulation and energy consumption of soot blowing, the base for water cooling wall soot blow optimization is the combustion house outlet gas temperature difference, the base for a single heat exchange surface soot blow optimization is the degree of its soot accumulation

    並對優化系統在線運行后,取得的實時計算結果和實際效果進行了分析,著重指出積灰和吹灰的經濟性最佳可作為整個鍋爐吹灰優化的決策依據,爐膛出口煙溫差可以作為爐膛吹灰優化決策的依據,受熱麵灰污程度可以作為單個對流受熱面吹灰優化決策的依據。
  4. The water temperature at the reactor pressure vessel outlet is about 330 degree c whereas the water temperature at the inlet of the vessel is about 290 degree c. the cooling water is in a sub - cooled condition at such high temperature and pressure to prevent it from boiling

    反應堆出水的溫度約為攝氏330度,而入水口的溫度約攝氏290度。在這高溫及高壓狀態下的冷卻水會處于欠熱狀態即冷卻水的溫度與其沸點有一段距離,因此不會沸騰。
  5. By the research on the raw materials, the mix proportion, the concrete temperature control in outlet, in transport and in placement, the cure and the post - cooling water, the synthetic measures for rcc dam construction in high temperature and the enforcement methods on basis of the computation and experience of jinghong hydropower station are presented in this paper

    本文通過對原材料及配合比、混凝土出機口溫度控制、運輸過程溫度控制、澆築過程的溫度控制以及混凝土澆筑後的養護和冷卻通水等一系列研究,提出景洪電站高氣溫條件下大壩碾壓混凝土連續施工的綜合措施,並在計算和已有經驗的基礎上給出具體實施方法。
  6. Temperature process lines with tidal cycles of multi engineering conditions of characteristic sections are obtained, the relationship between temperature distribution and velocity field is established, the inner mechanism change of temperature process lines is investigated, the interrelation between water intake and outlet is analyzed, the relation between the ratio of dimensionless temperature rise span of the plant intake and the ratio of river discharge volume and plant cooling water intake volume is obtained

    得到了特徵斷面多種工況隨潮周期變化的溫度過程線,建立了溫度場與流速場的相關關系,研究了溫度過程線的變化機理,分析了取排水口對溫度場的相互影響關系,探討了無量綱溫升時長比與無量綱來取流量比的相關關系。
  7. Mostly, including in the cubage of periodic sizing flash tank, steam exhaust pipe, draining pipe, cooling water line size, the cubage of continuing sizing flash tank. in chimney outlet velocity, the users should confirm the parameters of

    《擴容器和煙囪出口煙速選擇計算軟體系統》將為電力設計行業帶來極大的經濟效益和社會效益,同時也為電廠設計過程進一步現代化奠定了堅實的基礎。
  8. After the modification, the characteristic of outlet water of the spray nozzle is changed and the outlet temperature of the cooling water from the spray nozzle is decreased. as a result, the coal consumption is reduced and the efficiency of the steam turbine is better

    通過對噴濺裝置的改造,改變了噴頭的出水特性,從而降低了冷卻水出水溫度,提高了汽輪機真空和汽輪機熱效率,降低了煤耗,提高了機組運行的經濟性。