故障電阻 的英文怎麼說

中文拼音 [zhàngdiàn]
故障電阻 英文
fault resistance
  • : Ⅰ名詞1 (事故) event; incident; happening; accident 2 (原因) cause; reason 3 (朋友; 友情) fr...
  • : Ⅰ動詞(阻隔; 遮擋) block; hinder; obstruct Ⅱ名詞(遮擋物) barrier; block; obstacle
  • : Ⅰ名詞1 (有電荷存在和電荷變化的現象) electricity 2 (電報) telegram; cable Ⅱ動詞1 (觸電) give...
  • : 動詞(阻擋; 阻礙) block; hinder; impede; obstruct
  • 故障 : hitch; breakdown; stoppage; fault; faulting; accident; blunder; bug; conk; failure; impairment; i...
  • 電阻 : (物質阻礙電流通過的性質) resistance; electric resistance (電路中兩點間在一定壓力下決定電流強度...
  1. This paper presents a method that chopping wave is done by switch devices which consist of three - level resistance regulating module and intelligence power module ipm, and which realizes constant - current discharge of storage battery. to achieve the intelligence control of the drive protection and the discharge process of ipm, the paper designs circuit formed by igbt threshold drive pulse pwm signals. ipm fault - blocking protection circuit and microcomputer 80c196. the devices can accurately control the 0 ~ 150a discharge current and the discharge time of the storage battery and calculate the releasing power

    實現蓄池恆流放過程智能控制是蓄池放裝置發展的必然趨,本文提出了一種通過三極調節模塊和由智能功率模塊ipm為開關器件進行斬波從而實現蓄池恆流放的方法。為達到對ipm的驅動保護和放過程的智能控制,文中設計了igbt門極驅動脈沖pwm信號形成路和ipm封鎖保護路及由單片機80c196為核心的微機控制器。本裝置能夠對蓄池進行0 150a放流及放時間的精確控制及釋放容量的計算。
  2. The dsp - based drive logic for srm under fault conditions

    的開關磁機的帶運行的驅動邏輯研究
  3. Also, in case of a breakdown or serious delay in tram service due to traffic accidents leading to unfinished trips, passengers can get off the tram quickly via the front gate without paying for the trip

    此外,假如發生或交通意外等事令服務嚴重受,以致車未能把乘客送抵目的地,乘客即可不需繳付車資而迅速從前門下車。
  4. Fault location techniques are used to pinpoint location of the fault on a tra - nsmission line. transmission line faults must be located accurately to allow maintena - nce crew to arrive at the scene and repair the faulted section as soon as possible, which can relief the burdens of patrol personnel and reduce the revenue losses due to power outage. the accurate fault location alogrithms play an important role in power system safety, economy and reliability. in this paper, diversified fault location algorithms are summarized. according to the principles of algorithms, they can be classified into two categories : impedence based algorithm and traveling wave based algorithm. based on the analysis and comparission of each algorithm, the corresponding merits and app - lication limitations are presented

    精確的定位為現場巡線工作人員及時提供準確、可靠的信息,減輕人工巡線的負擔,同時加快線路的恢復供,減少因停造成的綜合經濟損失,為提高力系統運行的安全性、經濟性和可靠性發揮重要的作用。本文總結了現有的各種測距方法,根據測距的原理將其分為抗法和行波法兩大類,對各種演算法的優缺點及適用范圍進行了分析,在此基礎上提出了一種組合的測距方案,並對演算法進行了模擬分析。
  5. The development of a visual short circuit software under ptcad2000 is presented in this paper, as well as the system structure, the definition of the data structure, the interface to ptcad2000, the conversion of the original wiring diagram of power network to calculable power network, the implement of three sequence network, the implement of impendence matrix and admittance matrix of power network considering the zero sequence mutual inductances among lines, and the implement of short circuit calculation by using computer

    本文介紹了在ptcad2000平臺下短路流可視化計算軟體的開發。介紹了軟體的系統結構、數據結構定義、與ptcad2000平臺的介面、力系統原始接線圖轉成等值可計算網路、序網的生成、考慮零序互感線路抗時網導納矩陣和抗矩陣的生成,以及點短路流計算的計算機實現。
  6. Di - on electric one of the beijing hi - new - tech enterprise develop and manufacture lots of equipment like sf6 dewpoint meter dp100, cable fault location system cfl6000 and more. di - on electric supply the most advanced technology and equipment on such as gis surge arrestor on line monitoring, resistance measuring, ac dc metrology, thermal - temperature bridge, power transformer diagnostic and testing, cable diagnostic and fault location, sf6and oil moisture measuring, oil treatment and testing, optic fiber temperature monitoring, circuit breaker testing, relay testing and more

    迪揚氣在gis和避雷器的帶測試與診斷分析,纜的定位與局放檢測,變壓器抗器的各種測試診斷與溫度監測, sf6的水分測量與回收,絕緣油的測試分析與濾油處理,紅外測溫與光纖在線測溫,以及各種測試與計量,溫度計量與能計量等方面擁有世界一流的技術與成熟的儀器設備。
  7. The safety of transmission line plays a important role in power system safety it is not only the requirement of ensure supply power reliability, but also the necessary precondition of enhance power system stabilization, to remove faulty line quickly and accurately, also keep non - faulty line continuous work when some transmission line faults current differential protection is a kind of simple, reliable and good - selective protection manner to any variety of transmission lines, power system development needs current differential protection apply to transmission lines, moreover the advancement of electric and communication technology enable current differential protection apply to transmission lines firstly, the paper discusses, analyses the research and application transmission line protection in detail, compare the principle and realistic presupposition of general line pilot protections secondly, because conventional current vector differential protection are influenced easily by load current and transitional resistance, in order to at the same time quicken protection act, the principle and criterion include work characteristic of differential protect based on fault component sampled values are studied, results shows that differential protect based on fault component sampled values excels general vector current differential protection in reliability, sensitivity and anti - saturation of current transformer in addition, synchronous current sampling methods at all terminals of line is analyzed and estimated lastly, the principle and criterion. also device design about current sampling values differential protection based on optical fiber communication, which apply to short transmission lines are concretely investigated,

    基於基爾霍夫定律的流差動保護無論對於何種形式的輸線路都是一種簡單、可靠、選擇性強的保護形式,力系統的發展使得流差動保護應用於線路保護成為需要,而子、通信技術的發展使得流差動保護應用於輸線路成為可能。首先,本文對目前線路保護的研究和實際應用情況進行了討論和分析,比較了常用線路縱聯保護的實現原理和實現條件及優缺點。其次,針對常規相量流差動保護易受正常負荷流和過渡影響的缺點,同時為加快差動保護的動作速度,對基於分量瞬時采樣值流差動保護的原理、判據、動作特性等作了討論和分析,結果表明基於分量瞬時采樣值流差動保護在可靠性、靈敏度、抗流互感器飽和方面明顯優于常規相量流差動保護,對流差動保護各端的同步采樣方法和數據通信也進行了分析和評價。
  8. Equipped with electronic controller fini tronic and preset for remote control for two or more compressors. it offers working pressure and oil mist separator tank inner pressure indication, separator filter clogging lashing alarm before overpressure e - stop, electric motor temperature control, maximum screw assembly temperature control, air temperature on pressure end indication, electric motor direction of rotation check, time to scheduled maintenance term, total operating hours and operating hours under load, alarm log of last five failure events

    並預設為丙臺以上空壓機聯機遠程控制,有工作壓力和油氣分離器罐內壓指示,分離器過濾器塞報警,機溫控,螺桿總成溫控,壓力端空氣溫度指示,機轉向檢查,維護周期油,油過濾器,空氣過濾器,分離器過濾器,總運行時間和負載運行時間,記錄上五個報警等。
  9. The problem about neutral - point - grounding mode is an all - around technical problem which associated with not only power system reliability , insulation coordination , electromagnetic interference , but assault safety 。 in china , the neutral grounding modes of the 10kv net involved of none grounding, grounding by arc suppressing coils, resistance grounding or reactance grounding in the past 。 with the development of civic power network , low resistance grounding mode was used to restrain the over voltage, particularly in guangzhou, shanghai , beijing , and zhuhai etc. it was reported that the over - voltage level of low resistance grounding mode is lower than that of arc suppressing coil mode, but the operation carried out the other way 。 at substations in guangzhou and shanghai it was found that the low resistance grounding mode is successful 。 but in some areas , such as zhuhai , substations grounding with low resistance revealed some problems , including power supply reliability rapidly dropping , transmitting line often tripping ; and person safety being threatened 。 so interiorly the grounding mode selection of the 10kv network was disputed, which mainly focused on the fault form of 10kv net grounding, the apply area of suppressing arcing coil grounding mode, power supply reliability level of the two modes, person safety, communication interfere and the workload of maintenance

    爭議點主要是在10kv網接地的形式、消弧線圈接地的應用范圍、兩種運行方式供可靠性的高低、人身安全、通訊干擾和運行維護工作量等諸多方面。 11 17本論文就是針對以纜為主的城區10kv網中性點接地方式的選擇問題進行研究。論文首先對10kv網的中性點運行各種方式進行分析,比較各方式的特點,然後以重慶儲奇門變站10kv網的實際參數來建立數值計算模型,在考慮了網接地流變化、中性點取值大小、接地點接地值變化等多種影響因素的情況下,對中性點經消弧線圈接地和經小接地方式下網的過壓水平和接地點短路流大小進行了數值計算,其計算結果與科院所作現場試驗進行了比較。
  10. This paper analyzes detailedly the principles on distributed busbar protection - current instantaneous value differential method, impedance method, and put forward the new method of current fault component phase method, then compares with these methods

    本文詳細分析了分散式母線保護中的原理?瞬時值流差動法、抗法,提出了分量相位法的新方法,將這幾種方法進行比較。
  11. Then, this thesis presents an algorithn of 2 - terminal quantity fault location based on synchronous gps sampling. this algorithm conducts fault location with only the 3 - phase fundemental wave voltage and current phasors of the 2 terminals of transmission lines and apples to lines of both symmetrical and asymmetrical parameters, irrelerant to the impedence, fault types and transitional resistance of the 2 terminals of lines

    然後,本文提出了一種基於gps同步采樣的雙端量測距演算法。該演算法僅利用輸線路兩端的三相基波壓、流分量來進行定位,不受線路兩端系統抗、類型、過渡等因素的影響,對參數對稱線路和非對稱線路均適用。
  12. Because affected by the type of lines, fault resistance and two sides systems , fault analytical location has lower precision, but it has no dead line and is more better accurate if the fault location is close to the line terminal

    分析法由於受線路類型、過渡、兩端系統的影響測距精度較差,但分析法不存在測距死區,尤其對近區的測距較為準確。
  13. The results indicates the new hybrid bridge type sfcl using the inductance of the superconducting state and the impendence of the normal state of the superconductor could be more efficient in fault current limiting than the traditional bridge type sfcl

    結果表明,該拓撲結構同時利用了超導體超導態的感和失超后的來限制流,限流效果好,響應和復位速度快,是對橋式限流結構和混合型限流原理的有意義的探索。
  14. Have studied generator ground model mostly used in detail for middle and big domestic generator units. calculates and deduces fault current as grounding of single phase and third harmonic fault protection schemes. first time contributes overall knowledge about generator neutral grounding of distribution transformer with secondary resistor, in which considered inductance of the transformer to people

    針對大中型發機的兩種主要接地方式進行了分析,進行了接地流、三次諧波保護的計算推導,首次在接地變高接地方式有關公式推導中計入接地變感抗,從而使人們對接地變高接地認識更為全面。
  15. Under the conditions of high safe coefficient of insulated electrical strength of the stator winding of the generator, the selection of earthing resistance value should meet the needs of matching one - point earthing protection of the stator and limiting the fault current

    在發機定子繞組絕緣氣強度有較高的安全系數的情況下,接地值的選取應主要服從與定子一點接地保護的配合及限制接地流的需要。
  16. It is, of course, important to choose the resistor so that it neither degrades the noise performance of the system nor allows too much current to pass under fault conditions

    因此,限流的選擇十分重要,既要限制流,又不能引入太大的噪聲。
  17. By analyzing the refraction 、 reflection process of fault transient current traveling wave of high voltage and characteristics of refraction 、 reflection coefficient systematically, a new fault location method of single ended traveling wave is presented. it can not only identify the reflection wave for fault location efficiently, but also not be affected by the structure and length of line. fault earthed resistance 、 fault type 、 system impedance and can locate fault in adjacent areas accurately

    論文深入地分析了高壓線路暫態流行波的波折、反射過程以及折、反射系數的特點,提出了新的單端行波測距方法,它不僅能夠有效地識別出測距所用的反射波,而且幾乎不受線路結構、長短、接地類型、系統抗的影響,在近區仍可以準確地進行測距;同時模擬波器的特徵,設計了低通數字濾波器,對通過了低通數字濾波器的暫態流行波再次進行小波分析,並利用本文提出的單端行波測距方法進行定位,結論是所提出的測距方法在實際應用中仍是有效的。
  18. The merits of single terminal fault location are its reliability and its accuracy is n ' t affected by the type of line, fault resistance and two sides systems theoretically but this method has problems such as the identification of reflection wave and the unidentifiable area of reflection nearby which are research purpose and core of this paper

    單端行波測距方法的優點是其可靠性和精度在理論上不受線路類型、故障電阻及兩側系統的影響,但單端行波測距方法存在反射波的識別問題,且在近區還存在無法識別反射波區域。這就是本文的研究目的和中心。
  19. Up to now, although the fiber optical transmission network " s own monitor and management system are good, without other communication means, we can not judge what reason cause the abort of the fiber optical transmission network which has only one communication route by using the technique and means in existence

    目前,雖然光纖通信系統設備本身的監控管理比較完善,但當單路由光纖通信系統全局斷后,如果沒有其他通信手段,遠端站到底是發生光端機,還是光纜中斷造成的全局的斷,用現有的技術和手段無法判別。
  20. For fire grounding, grounded impedance varies greatly because of air dissociation, and this causes protection set to startup and resume again and again. therefore, the main protection of the fault line ca n ' t cut off the fault quickly and accurately, and may lead to overstep tripping of near lines " protection sets and eventually cause more serious faults on the power system

    同時流一般比較小,流突變也很小,有時呈緩慢上升的變化趨勢,對火焰接地來說,由於空氣游離的緣,接地抗變化很大,使現有保護反反復復啟動、恢復,可能會導致相鄰線路、設備的保護越級跳閘,使力系統出現更嚴重的
分享友人