立式冷凝器 的英文怎麼說

中文拼音 [shìlěngníng]
立式冷凝器 英文
vertical (type) condenser
  • : 動1 (站) stand; remain in an erect position 2 (使豎立; 使物件的上端向上) erect; stand; set up...
  • : 名詞1 (樣式) type; style 2 (格式) pattern; form 3 (儀式; 典禮) ceremony; ritual 4 (自然科...
  • : Ⅰ形容詞1 (溫度低; 感覺溫度低) cold:冷水 coldwater; 你冷不冷? do you feel cold?; are you feeling...
  • : 動詞1. (凝結) congeal; curdle; coagulate 2. (注意力集中) fix
  • : 名詞1. (器具) implement; utensil; ware 2. (器官) organ 3. (度量; 才能) capacity; talent 4. (姓氏) a surname
  1. Fini air treatment, recommended for the most demanding professional uses, is composed of refrigerating dryers, filters for separating impurities, condensate drain cocks, water - oil separators, tanks, and all other components necessary for optimising compressor operation

    Fini空氣處理系統,由藏乾燥組成,用過濾分開雜質,物排出管,水油分離,氣罐和其他空壓機必須的零部件組成,建議使用在大多數要求苛刻的專業用途。
  2. Heat exchangers - liquid cooled refrigerant condensers - test procedures for establishing the performance

    熱交換.液.性能確的試驗過程
  3. The plate - tube evaporator, the single back - fin evaporator and the box condenser. after analyzing the physical model and setting up the mathematical model according to the two - phase flow of adiabatic capillary tubes, it also numerically simulates and analyzes the different effects of main parameters on the capillary tube length. based on the heat transfer analysis and counting of thermal insulation layer, the cad system accomplishes the parametric design and drawings of the refrigerator body

    該系統完成了對典型製裝置的換熱部件,如板管蒸發、單脊翅片管蒸發、箱壁的參數化設計和繪圖;分析了絕熱型毛細管兩相流的物理模型,並建數學模型,對絕熱型毛細管各主要參數對其長度的影響進行了數值模擬和計算分析;基於對電冰箱箱體絕熱層厚度的傳熱分析和計算,完成了整個箱體的參數化設計和繪圖工作。
  4. In the project hong kong international wetland park phase ii, we take the initiative to install the first geothermal heat pump air - conditioning system and utilize the wetland around as a source of heat and a heat sink. through 468 pairs of vertical geothermal pipe heat exchanger buried in the wetland, heated water from water - cooled refrigeration plants and cool water from water source heat pump are circulated in a common condenser water loop to exchange their energy directly

    在香港國際濕地公園第二期工程項目,我們率先採用了香港首個地源熱泵空調系統,利用公園的濕地作為一個熱源及熱能儲存,透過468對埋放在濕地的直水管熱交換,將水空調系統的受熱水與地泵的凍水直接交換熱能。
  5. 2. various aluminium equipments : auto transportation tanker, horizontal and vertical storage tank, elevated tank, measuring tank and condenser

    製造各種鋁設備:汽車運輸槽車臥儲罐高位槽計量槽等。
  6. Research on the technology of self - cleaning fouling adhered to inside wall of tubes in vertical water coolers in refrigeration system

    系統管內污垢的自動清洗技術
  7. The condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    了空氣卻實驗臺,熱管的加熱方為電加熱,工質為蒸餾水.在1 1模型上對分離熱管管內結換熱特性、不性氣體對結換熱的影響及不性氣體的擴散規律進行了試驗,得出分離熱管有一最佳充液率,其值為45 %左右;結換熱系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不性氣體對分離熱管的結換熱僅影響段下部較小部分,通過排氣閥排出不性氣體可有效地改善段下部的結換熱;隨著壓力的增加,不性氣體對分離熱管段的影響減少.這些結論可用於分離熱管換熱的工程設計和控制
  8. Abstract : the condensation heat - exchange characteristic of a separate - type heat - pipe was studied on a 1 : 1 model. the heat pipe is heated by electricity, and working fluid is distilled water, and it is cooled by air. the experimental results show that, ( 1 ) when charging liquid ratio is 45 %, condensation heat - exchange coefficient reaches to maxium ; ( 2 ) when there is not non - condensing gas, the coeffcient decreases a little with the increase of vapour pressure, and it decreases by 9. 5 % when the pressure increases from 0. 16mpa to 0. 36mpa ; ( 3 ) when there is non - condensing gas, the coefficient decreases a little, but when the gas is discharged by an exhaust value, it can be improved, when the volume content of the gas is 2. 5 %, it can increased by 22 % ; ( 4 ) the effect of the non - condensing gas on the coefficient decreases with the increase of the pressure, and when the volume content of the gas is 5 % and the pressure increases from 0. 16mpa to 0. 36mpa, the coefficient increases by 6 %. the relative curves are given between condensation heat - exchange coefficient and air flowrate, charging liquid ratio and vapour pressure

    文摘:建了空氣卻實驗臺,熱管的加熱方為電加熱,工質為蒸餾水.在1 1模型上對分離熱管管內結換熱特性、不性氣體對結換熱的影響及不性氣體的擴散規律進行了試驗,得出分離熱管有一最佳充液率,其值為45 %左右;結換熱系數隨著蒸汽壓力的增加略有降低,在實驗的壓力范圍內,降低了9 . 5 % ;不性氣體對分離熱管的結換熱僅影響段下部較小部分,通過排氣閥排出不性氣體可有效地改善段下部的結換熱;隨著壓力的增加,不性氣體對分離熱管段的影響減少.這些結論可用於分離熱管換熱的工程設計和控制
  9. Meanwhile, in a distributed parameter approach a steady - state model of condenser and evaporator has also been established in the form of concentric counter - flow heat exchangers

    採用分佈參數法,建了復合螺旋套管和蒸發的穩態模型,並編制了和蒸發的設計和模擬軟體。
分享友人